Control Mode
6.7.2 Control structure
Full-closed loop control structure in PT mode
When the servo is in full-closed loop control in PT mode, if the E-Gear ratio is set to 1,
1
one pulse from the command corresponds to one quadruple-frequency pulse from the auxiliary
encoder. If the E-Gear ratio is set to 2, one pulse from the command corresponds to two
1
quadruple-frequency pulses from the auxiliary encoder.
6
GNUM0, GNUM1
1st numerator P1.044
2nd numerator P2.060
3rd numerator P2.061
4th numerator P2.062
Denominator P1.045
Error
counter
Position
control gain
P2.000
P1.084
Function when switching
to full-closed loop
(set to 0 to clear the error
when switching)
Speed loop
Speed
estimation
P1.072
Pulse number per
motor revolution
DI 0x0B
Full- / semi-closed loop switch
Encoder
Encoder
OA
pulse
pulse
OB
output
number
OZ
polarity
output
P1.003
P1.046
P1.074 Selection of OA/OB/OZ output source
P1.073
Protection range for the
feedback position
deviation between the
main encoder and
auxiliary encoder in
full-closed loop
Error
counter
Motor pulse
counter
Low-pass
filter
P1.075
Motor
Machine
Encoder
CN5
Auxiliary
encoder
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
6-41