Specifications and wiring descriptions for the CN5 signals:
Signal type
Operating voltage
Signal format
Encoder power (5V)
output
Pull-up resistor (R)
Max. pulse frequency
VHALL voltage
Hall sensor
5V
Single-ended
≤ 300 mA
≤ 20 kΩ*1
5 kHz
High-level voltage > 3.2V (Min.)
Low-level voltage < 2.2V (Max.)
A, B, Z phase signals
5V
Differential
≤ 300 mA
-
Single-phase pulse frequency: 4 MHz
-
Note:
1. If the servo drives are manufactured before week 50 of year 2017 (serial numbers: before T1750 and
W1750), they only support Hall sensors with
built-in pull-up resistors. If there is no built-in pull-up resistors, you need to connect to external ones.
2. If the servo drives are manufactured in week 50 of year 2017 or later (serial numbers: T1750 and
W1750, or later), the servo drives support Hall sensors with or without built-in pull-up resistors.