6.2.2 Position command in PR mode
The PR command source is the 100 built-in command registers, (P6.000, P6.001) - (P7.098,
P7.099). You can use DI (0x11) - DI (0x13), DI (0x1A) - DI (0x1C), and (0x1E) (POS0 - POS6 of
CN1) to select one of the 100 sets as the Position command and trigger the command with
DI.CTRG (0x08). See the following table for more details.
Position
command
POS6
Homing
0
PR#1
0
…
PR#50
0
PR#51
0
…
PR#99
1
POS5
0
0
1
1
1
POS4
0
0
1
1
0
POS3
0
0
0
0
0
POS2
0
0
0
0
0
POS1
0
0
1
1
1
POS0
0
1
0
1
1
CTRG
Corresponding
parameter
P6.000
↑
P6.001
P6.002
↑
P6.003
…
P6.098
↑
P6.099
P7.000
↑
P7.001
…
P7.098
↑
P7.099
Status of POS0 - POS6: 0 means that DI is off (the circuit is open); 1 means that DI is on (the
circuit is closed).
CTRG : indicates the moment the DI is switched from off to on.
The absolute type and incremental type position registers are used to control the operation
process. You can easily complete a periodic motor operation according to the preceding table.
For example, assume the Position command PR#1 is 10 turns and PR#2 is 20 turns. PR#1 is
issued first and PR#2 comes second. The following diagrams show the difference between
absolute and incremental positioning.
Absolute type
Incremental type
10 turns
20 turns
10 turns
20 turns
6-6