Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Control Mode
6.1 Selecting the control mode
This servo drive provides three basic control modes, Position, Speed, and Torque, and
communication modes. For basic operations, you can choose from Single mode, Dual mode,
and Multi-mode. The following table lists the available modes and corresponding descriptions.
Mode
Short name
Position mode
(Terminal block
PT
input)
Position mode
(Internal register)
PR
Speed mode
S
Single
mode
Speed mode
(No analog input)
Sz
Torque mode
T
Torque mode
(No analog input)
Tz
Code
Description
The servo drive receives the Position command
and commands the motor to run to the target
position.
00 The Position commands are communicated
through the terminal block and the signal type is
pulse.
The servo drive receives the Position command
and commands the motor to run to the target
position.
01 The Position commands are issued from the
internal registers (100 sets in total).
Select the register number with DI signals or
through communication.
The servo drive receives the Speed command
and commands the motor to run at the target
speed.
02
The Speed commands are issued from the
internal registers (3 sets in total) or by analog
voltage (-10V to +10V) which is communicated
through the external terminal block.
Select the command with DI signals.
The servo drive receives the Speed command
and commands the motor to run at the target
speed.
04 The Speed commands can only be issued from
the internal registers (3 sets in total) instead of
through the external terminal block.
Select the command with DI signals.
The servo drive receives the Torque command
and commands the motor to run with the target
torque.
03
The Torque commands are issued from the
internal registers (3 sets in total) or by analog
voltage (-10V to +10V) which is communicated
through the external terminal block.
Select the command with DI signals.
The servo drive receives the Torque command
and commands the motor to run with the target
torque.
05 The Torque commands can only be issued from
the internal registers (3 sets in total) instead of
through the external terminal block.
Select the command with DI signals.
6
6-3
Send Quote Requests to info@automatedpt.com