Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Tuning
When P2.027.X is set to 3 or 7 and P1.078 Gain switching delay time is set, the gain parameter
during the delay time is adjusted as follows.
P2.027.X = 3
P2.029
P0.002 = 6
Pulse command
frequency
Refer to the Before
switching column of
P2.027.Y
P2.027.X = 7
P1.078
P2.027.Y = 0
P2.000 x P1.079
P2.004 x P1.079
P2.006 x 100%
P2.026 x 100%
P2.049 x 100%
P2.025 x 100%
P2.027.Y = 1
P2.000 x P1.079
P2.004 x 100%
P2.006 x 0%
P2.026 x 0%
P2.049 x100%
P2.025 x 100%
Refer to the After Refer to the Before
switching column of switching column of
P2.027.Y
P2.027.Y
5
P2.029
P0.002 = 6
Pulse command
frequency
Gain switching
delay time
Gain switching
parameter
Refer to the Before
switching column of
P2.027.Y
P1.078
P2.027.Y = 0
P2.000 x P1.079
P2.004 x P1.079
P2.006 x 100%
P2.026 x 100%
P2.049 x 100%
P2.025 x 100%
P2.027.Y = 1
P2.000 x P1.079
P2.004 x 100%
P2.006 x 0%
P2.026 x 0%
P2.049 x100%
P2.025 x 100%
Refer to the After
switching column of
P2.027.Y
Relevant parameter
Refer to Chapter 8 for detailed descriptions.
Parameter
Function
P1.078
Gain switching delay time
P2.027
Gain switching condition and method selection
P2.028
Gain switching time constant
P2.029
Gain switching condition
Send Quote Requests to info@automatedpt.com