Test Operation and Panel Display
P0.002
setting value
Monitoring symbol
25
26
27
28
Description
Monitoring variable #3: shows the content of parameter
P0.011
(Specify the monitoring variable code by P0.019)
Monitoring variable #4: shows the content of parameter
P0.012
(Specify the monitoring variable code by P0.020)
Offset value between motor position and Z phase.
(Only available for Delta CNC controllers.)
The alarm code (in decimal). The value being
converted to the hexadecimal notation is identical to
the alarm code displayed in P0.001 and the error code
of communication models.
Unit
-
-
PUU
-
29
Position feedback from the auxiliary encoder.
PUU
30
Position difference between the position feedback and
the command from the auxiliary encoder.
PUU
31
Feedback position difference between the main
encoder and auxiliary encoder.
PUU
The following table shows the panel display of 16-bit and 32-bit values.
Example of
the displayed value
Description
(Dec)
(Hex)
16 bits
If the value is 1234, it displays 01234 (in decimal format).
If the value is 0x1234, it displays 1234 (in hexadecimal format;
the first digit does not show).
(Dec high)
(Dec low)
32 bits
(Hex high)
(Hex low)
If the value is 1234567890, the display of the high word is
1234.5 and the display of the low word is 67890 (in decimal
format).
If the value is 0x12345678, the display of the high word is
h1234 and the display of the low word is L5678 (in
hexadecimal format).
4
4-9