Wiring
3.6 Wiring for the CN3 connector (RS-485 / high-speed
communication)
When the servo drive is connected to the PC via the CN3 connector, you can operate the servo
drive, PLC, or HMI through Modbus using the assembly language. The CN3 connector supports
two commonly used communication interfaces, RS-485 and CAN, allowing you to connect
multiple servo drives simultaneously.
Note:
1. A3-L: single port (Pin 1 - Pin 8); supports RS-485 but does not support high-speed communication
(CANopen).
2. A3-M: dual ports; support both RS-485 and high-speed communication (CANopen).
3
(1) CN3 connector (female); (2) CN3 connector (male)
Pin assignment:
Pin No.
1
2
3, 7
4
5
6, 8
9
10
11, 15
12
13
14, 16
Signal
CAN_H
CAN_L
GND_ISO
RS-485-
RS-485+
-
CAN_H
CAN_L
GND_ISO
RS-485-
RS-485+
-
Description
CAN_H bus line (dominant high)
CAN_L bus line (dominant low)
Signal GND
For the servo drive to transmit the data to differential
terminal (-).
For the servo drive to transmit the data to differential
terminal (+).
Reserved
CAN_H bus line (dominant high)
CAN_L bus line (dominant low)
Signal GND
For the servo drive to transmit the data to differential
terminal (-).
For the servo drive to transmit the data to differential
terminal (+).
Reserved
Note: refer to Chapter 9 for the RS-485 wiring.