Wiring
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA -A3
3
DI wiring - input signals by relay or open collector transistor.
Conditions of DI On / Off:
ON: 15V - 24V; condition: input current = 8 mA.
OFF: 5V or below; the input current must not be higher than 0.5 mA.
C7: NPN transistor (SINK mode)
DC 24V
Servo drive
COM+
Approx. 4.7 KΩ
DI
C8: PNP transistor (SOURCE mode)
DC 24V
Servo drive
DI
COM+
Approx. 4.7 KΩ
3-100