Wiring
The A3-F and A3-E series models provide user-defined I/Os for you to set functions according
to the application requirements. See Chapter 8 and refer to Table 8.1 Digital input (DI)
descriptions and Table 8.2 Digital output (DO) descriptions. The default DI/DO signal
configuration for each control mode includes the most commonly used functions and meets the
requirements for general applications. To reset the signals to the default values of each
corresponding mode, set P1.001.U to 1 and cycle the power to the servo drive.
See the following table for the default DI signal of each control mode:
Control mode
PT
PR
S / Sz
T / Tz
PT-S
PT-T
PR-S
DI
Default
Default
Default
Default
Default
Default
Default
Signal
Signal
Signal
Signal
Signal
Signal
Signal
0x01
0x01
0x01
0x01
0x01
0x01
0x01
1
SON
SON
SON
SON
SON
SON
SON
0x04
0x08
0x09
0x10
0x04
0x04
0x08
2
CCLR
CTRG
TRQLM SPDLM
CCLR
CCLR
CTRG
0x16
0x11
0x14
0x16
0x14
0x16
0x11
3
TCM0
POS0
SPD0
TCM0
SPD0
TCM0
POS0
0x02
0x02
0x02
0x02
-
4
ARST
ARST
ARST
ARST
-
-
0x12
-
POS1
0x22
0x22
0x22
0x02
-
5
NL
NL
NL
ARST
-
-
0x14
-
SPD0
0x23
0x23
0x23
0x22
0x18
0x20
0x18
6
PL
PL
PL
NL
S-P
T-P
S-P
0x21
0x21
0x21
0x21
0x21
0x21
0x21
7
EMGS
EMGS
EMGS
EMGS
EMGS
EMGS
EMGS
3