Wiring
DI wiring - input signals by relay or open collector transistor.
Conditions of DI On / Off:
ON: 15V - 24V; condition: input current = 8 mA.
OFF: 5V or below; the input current must not be higher than 0.5 mA.
C7: NPN transistor (SINK mode)
DC 24V
Servo drive
COM+
Approx. 4.7 KΩ
3
DI
C8: PNP transistor (SOURCE mode)
DC 24V
Servo drive
DI
COM+
Approx. 4.7 KΩ
C9: output for encoder position signal (line driver)
A3-L / A3-M servo drive Max. current output: 20 mA
AM26C31 series
OA (21)
Controller
/OA (22)
120 Ω
OB (25)
/OB (23)
120 Ω
OZ (50)
/OZ (24)
120 Ω
SG
Note: it is suggested that you connect the two GNDs for the controller and servo drive in parallel when the