Send Quote Requests to info@automatedpt.com
Wiring
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA -A3
3
Caution: when the drive connects to an inductive load, you must install the diode.
DO specification:
Permissible current: below 40 mA; surge current: below 100 mA; maximum voltage: 30V.
Diode specification:
1A or above, 500V or above (e.g., 1N4005).
C5: DO wiring - the servo drive uses an external power supply and the resistor is for general
load.
Servo drive
DOX+
DOX-
R
24 VDC
C6: DO wiring - the servo drive uses an external power supply and the resistor is for inductive
load.
Servo drive
Make sure the polarity of
diode is correct, or it may
damage the servo drive.
DOX+
DOX-
24 VDC
3-86
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com