Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Wiring
You can input the pulse command with the open collector or line driver. The maximum input
pulse is 4 Mpps for the line driver and 200 kpps for the open collector.
Caution: when the source for the pulse input is open collector NPN type or PNP type
equipment, you must connect the external power (24V ± 10%) to the PULL HI pins.
Do not connect the 24V power to the SIGN+ and SIGN- pins at the same time, or the
circuit elements will be damaged.
Do not connect the 24V power to the PULSE+ and PULSE- pins at the same time, or
the circuit elements will be damaged.
C3-1: the source for the pulse input is open-collector NPN-type device, which uses the external
power supply.
Controller without built-in resistor
Controller
A3-L / A3-M servo drive
3
+ DC
- 24V
35 PULL HI_S
1.5 KΩ
51 Ω
Max. pulse input
frequnecy:
200 Kpps
37 SIGN-
51 Ω
39 PULL HI_P
1.5 KΩ
51 Ω
41 PULSE- 51 Ω
Max. pulse input
frequency:
200 Kpps
SG
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
3-83