Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Wiring
There are various control modes available (refer to Section 6.1) and the I/O configuration differs
for each mode. The A3-L and A3-M series models provide user-defined I/Os for you to set
functions according to the application requirements. See Chapter 8 and refer to Table 8.1 Digital
input (DI) descriptions and Table 8.2 Digital output (DO) descriptions. The default DI/DO signal
configuration for each control mode includes the most commonly used functions and meets the
requirements for general applications. To reset the signals to the default values of each
corresponding mode, set P1.001.U to 1 and cycle the power to the servo drive.
See the following table for the default DI signal of each control mode:
Control mode
PT
PR
S / Sz
T / Tz
PT-S
DI
Default
Default
Default
Default
Default
Signal
Signal
Signal
Signal
Signal
0x01
0x01
0x01
0x01
0x01
1
SON
SON
SON
SON
SON
0x04
0x08
0x09
0x10
0x04
2
CCLR
CTRG
TRQLM SPDLM
CCLR
0x16
0x11
0x14
0x16
0x14
3
TCM0
POS0
SPD0
TCM0
SPD0
0x17
0x12
0x15
0x17
0x15
4
TCM1
POS1
SPD1
TCM1
SPD1
0x02
0x02
0x02
0x02
-
5
ARST
ARST
ARST
ARST
-
0x22
0x22
0x22
0x22
-
6
NL
NL
NL
NL
-
0x23
0x23
0x23
0x23
0x18
7
PL
PL
PL
PL
S-P
0x21
0x21
0x21
0x21
0x21
8
EMGS
EMGS
EMGS
EMGS
EMGS
9
-
-
-
-
-
10
-
-
-
-
-
PT-T
Default
Signal
0x01
SON
0x04
CCLR
0x16
TCM0
0x17
TCM1
-
-
-
-
0x20
T-P
0x21
EMGS
-
-
PR-S
Default
Signal
0x01
SON
0x08
CTRG
0x11
POS0
0x12
POS1
0x14
SPD0
0x15
SPD1
0x18
S-P
0x21
EMGS
-
-
3
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
3-73