3.2.3 Wiring for power supply
The power supply wiring for the 400V series servo drive is three-phase. In the following
diagram, Power 1 and ALRM_RY_A are normally open contacts, and Power 2 is a normally
closed contact. MC (magnetic contactor) is the power relay and the contact for the main power
circuit.
Wiring method for three-phase power supply (for all 400V series)
T SR
MCCB
Noise filter
Power 1 Power 2
MC ALRM_RY_A
MC
SPD
DC 24V
Power supply
R Servo drive
U
S
V
T
W
MC
DC 24V
DC 0V
P1
P2
Note:
MCCB: molded case circuit breaker
MC: magnetic contactor
SPD: surge protection device
Power 1: power on
Power 2: power off
ALRM_RY: alarm relay
ALRM_RY_A: normally open contact
of the alarm relay
CN1
DO+
DO-
Note: wire the CN1 connector with the actual DO parameters of each model.