3.1.7.2 F100 - F180 models (4.5 kW or below) – power connector
a
b
Step 1:
Cut through the cable and expose the
shielding. The exposed wire length (a)
should be 23 - 27 mm (0.9 - 1.06 inches)
for straight connectors and 28 - 32 mm
(1.1 - 1.26 inches) for right angle
connectors, and the tinned wire length (b)
should be 3 - 5 mm (0.12 - 0.2 inches).
(D)
(C) (B) (A)
Step 2:
Place the (A) seals nut, (B) rubber ring,
(C) black compression ring, and
(D) straight or angle connector on the
cable in sequence.
Note: use the rubber ring corresponding to the
cable in order to meet the IP67 standard.
(E)
(D)
(E)
(D)
Step 3:
For the power connector, refer to
Section 3.1.4 for the pin assignment
to connect the pins.
For the encoder connector, refer to
Section 3.1.5 for the pin assignment
to connect the pins.
Note: it is suggested that you use 20 mm
(0.79 inches) heat shrink for straight
connectors, and 25 mm (0.98 inches) heat
shrink for right angle connectors.
Step 4:
Tighten (D) and (E) with adequate torque.
For the torque value, refer to Section
3.1.7.3 for IP67 waterproof connector
installation and wiring specifications.
(E) + (D)
(C) + (B)
Step 5:
Place (B) in (C), and then place (C) + (B)
in (D).
(D)
(A)
Step 6:
Tighten (A) and (D) at the torque of
10 Nm.
3-52