Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
Wiring
3.1.6.4 Encoder cable specifications
Item
Model name
Specification
Standard cable
ACS3-CAEN01XX
ACS3-CAEA01XX
ACS3-CAEN11XX
ACS3-CAEA11XX
ACS3-CAENA1XX
ACS3-CAEAA1XX
ACS3-CRENA1XX
ACS3-CREAA1XX
UL2464 (Temp. rating: 80°C / 176°F)
Flexible cable
ACS3-CAEF01XX
ACS3-CAEB01XX
ACS3-CAEF11XX
ACS3-CAEB11XX
ACS3-CAEFA1XX
ACS3-CAEBA1XX
ACS3-CREFA1XX
ACS3-CREBA1XX
UL2464 (Temp. rating: 80°C / 176°F)
DC+5V / GND
AWG#22-2C (0.32 mm²)
Outer diameter of insulated wire: Φ1.3 mm
AWG#22-2C (0.32 mm²)
Outer diameter of insulated wire: Φ1.3 mm
T+ / T-
Cable outer diameter
Max. wiring length
Standard length
provided by Delta
AWG#24-2P (0.21 mm²)
Outer diameter of insulated wire: Φ1.1 mm
AWG#24-2P (0.21 mm²)
Outer diameter of insulated wire: Φ1.1 mm
Φ7 mm
20 m
L = 3 m, 5 m, 10 m, 20 m
3
Item
Model name
Specification
Standard cable
ACS3-AFEASIXX
ACS3-ABEASIXX
ACS3-AFEASAXX
ACS3-ABEASAXX
UL20276 (Temp. rating: 80°C / 176°F)
Flexible cable
ACS3-AFERSIXX
ACS3-ABERSIXX
ACS3-AFERSAXX
ACS3-ABERSAXX
UL20276 (Temp. rating: 80°C / 176°F)
DC+5V / GND
AWG#22-2C (0.32 mm²)
Outer diameter of insulated wire: Φ1.3 mm
AWG#22-2C (0.32 mm²)
Outer diameter of insulated wire: Φ1.3 mm
T+ / T-
AWG#26-2P (0.13 mm²)
Outer diameter of insulated wire: Φ1.1 mm
AWG#26-2P (0.13 mm²)
Outer diameter of insulated wire: Φ1.1 mm
Cable outer diameter
Φ5.8 - Φ6.2 mm
Max. wiring length
Standard length
provided by Delta
20 m
L = 3 m, 5 m, 10 m, 20 m
Note:
1. Use a shielded twisted-pair cable to reduce the noise interference.
2. The shield should connect to the phase of the ground terminal.
3. When wiring, use the wires suggested in this section to avoid danger.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
3-43