Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Specifications
Motor frame size: 80 mm and below (high inertia)
ECM-
B3H-C0602
B3H-C0604
B3H-C0807
Rated power (kW)
0.2
0.4
0.75
Rated torque (N·m)*1
0.64
1.27
2.4
Max. torque (N·m)
2.43
4.83
9.12
Rated speed (rpm)
3000
3000
3000
Max. speed (rpm)
6700
6700
6700
Rated current (Arms)
1.51
2.21
4.19
Max. instantaneous current (Arms)
6.12
8.46
16.3
Change of rated power w/o brake
15.5
(kW/s)
with brake
14.6
30.8
37.2
30.0
35.6
Rotor inertia
(× 10-4 kg·m2)
w/o brake
with brake
0.265
0.280
0.523
1.55
0.538
1.62
Mechanical time w/o brake
1.78
constant (ms)
with brake
1.88
1.31
0.825
1.34
0.862
Torque constant-KT (N·m/Arms)
0.424
0.575
0.573
Voltage constant-KE (mVrms/rpm)
15.3
20.8
20.2
Armature resistance (Ohm)
4.17
2.85
0.588
Armature inductance (mH)
2
3.5
1
Electrical time constant (ms)
0.48
1.23
1.70
w/o brake
0.70
Weight (kg)
with brake
1.23
1.05
2.15
1.6
2.95
Max. radial load (N)
245
245
392
Max. axial load (N)
74
74
147
Brake operating voltage
24 VDC ± 10%
Brake power consumption (W)
(at 20˚C (68°F))
7.6
7.6
8
Brake holding torque
[N·m (Min)]*2
1.3
1.3
2.5
Brake release time [ms (Max)]
20
20
20
Brake pull-in time [ms (Max)]
50
50
60
Derating rate with oil seal (%)
10
5
5
Insulation class
Class A (UL), Class B (CE)
Insulation resistance
Insulation strength
Vibration grade
Ambient temperature
100 MΩ min. (at 500 VDC)
1.8 kVAC, 1 sec
V15
-20˚C to +60˚C (-4°F to +140°F)*3
Storage temperature
-20˚C to +80˚C (-4°F to +176°F)
Ambient and storage humidity
20 - 90% RH (non-condensing)
Vibration capacity
2.5 G
IP rating
IP67 (for models using waterproof connectors and shaft seals or oil seals)
Approvals
A
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
A-29