Send Quote Requests to info@automatedpt.com
Specifications
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
A
Item
Protection function
Communication interface
Installation site
Altitude
Atmospheric pressure
Operating temperature
Storage temperature
Humidity
Vibrating
Pollution degree
IP rating
Power system
Approvals*4
Specification
Overcurrent, Overvoltage, Undervoltage, Overheat, Regeneration
error, Overload, Excessive speed deviation, Excessive position
deviation, Encoder error, Calibration error, Emergency stop,
Positive / negative limit error, Serial communication error, RST power
error, Serial communication timeout, Short-circuit protection for
terminals U, V, W.
RS-485 / USB / CANopen / DMCNET / EtherCAT
Indoors (avoid direct sunlight),
no corrosive vapor (avoid fumes, flammable gases, and dust)
Less than 2,000 m above sea level
86 kPa - 106 kPa
0˚C to 55˚C (32˚F to 131˚F)
(When operating the 3 kW model at 50°C to 55°C (122˚F to 131˚F),
decrease the rated load to 80%.)
If the temperature is over 45°C (113°F),
place the product in a well-ventilated environment.
-20˚C to +65˚C (-4˚F to 176˚F)
Under 0 - 90% RH (non-condensing)
10 Hz - 57 Hz: 0.075 mm amplitude; 58 Hz - 150 Hz: 1G
Degree 2
IP20*3
TN system / TT system
IEC/EN/UL 61800-5-1
Note:
1. Within the rated load, the speed ratio is: the minimum speed (smooth operation) / rated speed.
2. Within the rated speed, the speed calibration ratio is: (rotational speed with no load - rotational speed
with full load) / rated speed.
3. The terminal blocks are not IP20 rated.
4. Please visit Delta website to download the certificates.
5. This equipment does not have functions of thermal memory for shutdown, thermal memory for loss of
power, and speed sensitivity in accordance with EN 61800-5-1:2007/A1:2017.
6. To meet the functional safety requirement, install the servo drive in the cabinet with a rating of IP54 or
higher.
A-8
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com