Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Troubleshooting
ALF22 Password does not match
Trigger condition
and cause
Condition: the password of the second development platform project does not
match that of the servo drive.
Cause: the password of the second development platform project does not match
that of the servo drive.
Checking method Check if the password of the second development platform and the password of
and corrective action the servo drive are input correctly.
How to clear the
alarm?
1. You can change the password of the second development platform project
with the EzASD software, but you cannot reset the password.
2. You can change the servo drive password with the EzASD software.
You can also set P2.008 to 10 to reset the servo drive password.
Note that setting P2.008 to 10 not only resets all parameters but also clears
the second development platform projects stored in the servo drive.
14
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
14-89