Send Quote Requests to info@automatedpt.com
Troubleshooting
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
14
ALE04 Fagor encoder - sensor signal strength warning
Condition: an error occurred to the Fagor encoder.
Cause:
Trigger condition
and cause
1. Analog signal of the sensor < 0.4 Vpp.
2. The installation or wiring of the encoder is incorrect.
3. The installation and operating environment do not meet the specifications,
causing encoder error.
4. The encoder is damaged.
1. Make sure the encoder or read head is correctly installed and wired according
Checking method
and corrective action
to the manufacturer’s instruction manual.
2. If the issue persists, contact the distributor of the encoder.
How to clear the
alarm?
DI.ARST
ALE05 Fagor encoder - voltage warning
Condition: an error occurred to the Fagor encoder.
Cause:
Trigger condition
and cause
1. The encoder voltage is abnormal.
2. The installation or wiring of the encoder is incorrect.
3. The installation and operating environment do not meet the specifications,
causing encoder error.
4. The encoder is damaged.
1. Make sure the encoder or read head is correctly installed and wired according
Checking method
and corrective action
to the manufacturer’s instruction manual.
2. If the issue persists, contact the distributor of the encoder.
How to clear the
alarm?
DI.ARST
14-86
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com