Troubleshooting
ALE02 Fagor encoder - CCD error
Condition: an error occurred to the Fagor encoder.
Cause:
Trigger condition
and cause
1. The installation or wiring of the encoder is incorrect.
2. The installation and operating environment do not meet the specifications,
causing encoder error.
3. The encoder is damaged.
1. Make sure the encoder or read head is correctly installed and wired according
Checking method
and corrective action
to the manufacturer’s instruction manual.
2. If the issue persists, contact the distributor of the encoder.
How to clear the
alarm?
DI.ARST
14
ALE03 Fagor encoder - position error
Condition: an error occurred to the Fagor encoder.
Cause:
Trigger condition
and cause
1. Analog signal of the sensor < 0.2 Vpp.
2. The installation or wiring of the encoder is incorrect.
3. The installation and operating environment do not meet the specifications,
causing encoder error.
4. The encoder is damaged.
Checking method
and corrective
action
1. Make sure the encoder or read head is correctly installed and wired according
to the manufacturer’s instruction manual.
2. If the issue persists, contact the distributor of the encoder.
How to clear the
alarm?
DI.ARST