ALD24 EnDat 2.2 encoder - temperature warning
Condition: an error occurred to the EnDat 2.2 encoder.
Cause:
Trigger condition
and cause
1. The installation or wiring of the encoder is incorrect.
2. The installation and operating environment do not meet the specifications,
causing encoder error.
3. The encoder is damaged.
1. Make sure the encoder or read head is correctly installed and wired according
Checking method
and corrective action
to the manufacturer’s instruction manual.
2. If the issue persists, contact the distributor of the encoder.
How to clear the
alarm?
DI.ARST or cycle power on the servo drive.
ALD25 EnDat 2.2 encoder - sensor signal strength warning
Condition: an error occurred to the EnDat 2.2 encoder.
Cause:
Trigger condition
and cause
1. The installation or wiring of the encoder is incorrect.
2. The installation and operating environment do not meet the specifications,
causing encoder error.
3. The encoder is damaged.
1. Make sure the encoder or read head is correctly installed and wired according
Checking method
and corrective action
to the manufacturer’s instruction manual.
2. If the issue persists, contact the distributor of the encoder.
How to clear the
alarm?
DI.ARST or cycle power on the servo drive.
14-80
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com