Troubleshooting
ALD02 MITUTOYO encoder - hardware error
1. Make sure the encoder or read head is correctly installed and wired according
Checking method
and corrective action
to the manufacturer’s instruction manual.
2. If the issue persists, contact the distributor of the encoder.
How to clear the
alarm?
DI.ARST or cycle power on the servo drive.
14
ALD03 MITUTOYO encoder - absolute position detection error
Condition: an error occurred to the MITUTOYO encoder.
Cause:
Trigger condition
and cause
1. The absolute position is in error.
2. The installation or wiring of the encoder is incorrect.
3. The installation and operating environment do not meet the specifications,
causing encoder error.
4. The encoder is damaged.
1. Make sure the encoder or read head is correctly installed and wired according
Checking method
and corrective action
to the manufacturer’s instruction manual.
2. If the issue persists, contact the distributor of the encoder.
How to clear the
alarm?
DI.ARST or cycle power on the servo drive.
ALD04 MITUTOYO encoder - sensor or read head error
Condition: an error occurred to the MITUTOYO encoder.
Cause:
Trigger condition
and cause
1. The sensor signal is in error.
2. The installation or wiring of the encoder is incorrect.
3. The installation and operating environment do not meet the specifications,
causing encoder error.
4. The encoder is damaged.
Checking method
and corrective
acction
1. Make sure the encoder or read head is correctly installed and wired according
to the manufacturer’s instruction manual.
2. If the issue persists, contact the distributor of the encoder.
How to clear the
alarm?
DI.ARST or cyhcle power on the servo drive.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com