Send Quote Requests to info@automatedpt.com
Troubleshooting
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
14
ALD00 MITUTOYO encoder - overspeed
Condition: an error occurred to the MITUTOYO encoder.
Cause:
Trigger condition
and cause
1. The motor speed exceeds 3 m/s.
2. The installation or wiring of the encoder is incorrect.
3. The installation and operating environment do not meet the specifications,
causing encoder error.
4. The encoder is damaged.
1. Make sure the encoder or read head is correctly installed and wired according
Checking method
and corrective action
to the manufacturer’s instruction manual.
2. If the issue persists, contact the distributor of the encoder.
How to clear the
alarm?
DI.ARST or cycle power on the servo drive.
ALD01 MITUTOYO encoder - initialization error
Condition: an error occurred to the MITUTOYO encoder.
Cause:
Trigger condition
and cause
1. Initialization status error.
2. The installation or wiring of the encoder is incorrect.
3. The installation and operating environment do not meet the specifications,
causing encoder error.
4. The encoder is damaged.
1. Make sure the encoder or read head is correctly installed and wired according
Checking method
and corrective action
to the manufacturer’s instruction manual.
2. If the issue persists, contact the distributor of the encoder.
How to clear the
alarm?
DI.ARST or cycle power on the servo drive.
ALD02 MITUTOYO encoder - hardware error
Condition: an error occurred to the MITUTOYO encoder.
Cause:
Trigger condition
and cause
1. The encoder hardware signal is in error.
2. The installation or wiring of the encoder is incorrect.
3. The installation and operating environment do not meet the specifications,
causing encoder error.
4. The encoder is damaged.
14-72
Send Quote Requests to info@automatedpt.com