AL237 Rotary axis position is undefined
Trigger condition
and cause
The starting point of the rotary axis position is not defined before you operate the
rotary axis position control and execute the rotary axis positioning command. This
alarm occurs because the servo drive cannot identify the rotary axis position
system.
Checking method Check if the rotary axis position is undefined: perform the homing procedure before
and corrective action using the rotary axis position control to avoid triggering this alarm.
How to clear the
alarm?
DI.ARST
AL239 Second development platform - the argument of the LOOP_CMD command is out of
range
Trigger condition
and cause
Condition: when the LOOP_CMD command is used, the input argument is out of
range.
Cause: incorrect use of the command of the second development platform.
Checking method
and corrective action
Refer to the command descriptions for the second development platform to ensure
the correct use of the commands. If you took the corrective action but the issue
persists, contact the local distributor or technician.
How to clear the
alarm?
DI.ARST
AL23F Second development platform - parameter is written to a memory address that is out
of range
Trigger condition
and cause
Condition: when the command for writing the parameter is used, the parameter is
written to a memory address that is out of range.
Cause: incorrect use of the command of the second development platform.
Checking method
and corrective action
Refer to the command descriptions for the second development platform to ensure
the correct use of the commands. If you took the corrective action but the issue
persists, contact the local distributor or technician.
How to clear the
alarm?
DI.ARST
AL245 PR positioning timeout
Trigger condition
and cause
Condition: PR positioning function is triggered.
Cause: the time for executing positioning is too long.
Checking method Check if the conditions for completing the PR commands are not set or not
and corrective action triggered causing the PR command incomplete.
How to clear the
alarm?
DI.ARST or cycle power on the servo drive.