Troubleshooting
AL213 Parameter setting of Type [8] PR is in error
Trigger condition
and cause
Condition: when you use Type [8] PR command to write the parameter,
the parameter value is incorrect.
Cause: an error occurs when you write the parameter with Type [8] PR command.
Checking method
and corrective action
Make sure the parameter value is within the correct range.
How to clear the
alarm?
DI.ARST
14
AL215 Parameter written by Type [8] PR is read-only
Trigger condition
and cause
Condition: the read-only parameter is written by Type [8] PR command.
Cause: an error occurs when you write the parameter with Type [8] PR command.
Checking method
and corrective action
The specified parameter is read-only.
How to clear the
alarm?
DI.ARST
AL217 Parameter written by Type [8] PR is write-protected when Servo On
Trigger condition
and cause
Condition: when you use Type [8] PR command to write the parameter, the
parameter is write-protected when the servo drive is On or the parameter value
exceeds the range.
Cause: an error occurs when you write the parameter with Type [8] PR command.
Checking method Write the parameter when the servo drive is Off and make sure the parameter
and corrective action value is within the range.
How to clear the
alarm?
Modify the PR command and the parameter.
AL219 Parameter written by Type [8] PR is write-protected
Trigger condition
and cause
Condition: the parameter written by Type [8] PR command is write-protected.
Cause: the parameter write-protected function is enabled.
Checking method
and corrective action
Check if the parameter and data array protection function (P5.097) is enabled.
How to clear the
alarm?
Disable the parameter and data array protection function or reset the parameters.
AL21B Second development platform - memory stack is out of range
Trigger condition
and cause
Condition: when a stack control command is used, the memory address is out of
range.
Cause: incorrect use of the command of the second development platform.
Checking method
and corrective action
Refer to the command descriptions for the second development platform to ensure
the correct use of the commands. If you took the corrective action but the issue
persists, contact the local distributor or technician.