Send Quote Requests to info@automatedpt.com
Troubleshooting
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
14
AL207 Parameter group of Type [8] PR is out of range
Trigger condition
and cause
Condition: when Type [8] PR command specifies Parameter as the data source,
the parameter group is out of range.
Cause: parameter group exceeds the range.
Checking method
and corrective action
Write parameter using PR procedure: when the data source is Parameter and the
group setting exceeds the range, check the setting range of the group for the
written parameters.
How to clear the
alarm?
DI.ARST
AL209 Parameter number of Type [8] PR is out of range
Trigger condition
and cause
Condition: when Type [8] PR command specifies Parameter as the data source,
the parameter number is out of range.
Cause: parameter number exceeds the range.
Checking method
and corrective action
Write parameter using PR procedure: when the data source is Parameter and the
parameter number setting exceeds the range, check the setting range of the
number for the written parameters.
How to clear the
alarm?
DI.ARST
AL211 Parameter format setting of Type [8] PR is in error
Condition: parameter format setting of Type [8] PR command is in error.
Trigger condition
and cause
Cause:
1. Incorrect parameter format.
2. The ASDA-Soft software version and the firmware version do not match.
1. Check if the parameter format is correct.
Checking method 2. Check if you are using the latest version of the ASDA-Soft software.
and corrective action If you took the corrective actions but the issue persists, contact the local distributor
or technician.
How to clear the
alarm?
DI.ARST
14-56
Send Quote Requests to info@automatedpt.com