Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Troubleshooting
AL026 Encoder unreliable internal data
Condition: internal data error occurs three consecutive times.
Trigger condition
and cause
Cause:
1. External interference.
2. Malfunction of the encoder hardware.
If there is interference, check the following items:
1. Check if the motor is properly grounded. Make sure the ground end (encd) of
the power cable is grounded to the servo drive heat sink.
2. Check if the connection for the encoder signal cable is normal. Make sure the
encoder signal cable is separated from the power supply or any high-current
Checking method
cables to avoid interference.
and corrective action 3. Use shielded cable for the encoder cable. Pull out the wire mesh and have it
correctly grounded.
How to clear the
alarm?
4. Check the communication error rate by setting P0.002 to -80. If the value is
greater than 0 and increases continuously, check the previous three items
again. If the value is 0, send your servo motor back to the distributor or
contact Delta.
Cycle power on the servo drive.
14
AL027 Encoder internal reset error
Trigger condition
and cause
Condition: encoder reset error.
Cause: encoder reset.
1. Check if there is poor connection for the encoder signal cable.
2. Check if the power supply for the encoder is stable and make sure to use
shielded cable.
Checking method
and corrective action
3.
Check if the operating temperature is over 95°C (203°F). Identify the cause for
the high temperature and do not restart the operation before the temperature
drops to the allowable range.
How to clear the
alarm?
If the issue persists, send your servo motor back to the distributor or contact Delta.
Cycle power on the servo drive.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
14-21