EtherCAT Mode
Object 6068h: Position window time
Index
Name
Object code
Data type
Access
PDO mapping
Setting range
Default
Unit
6068h
Position window time
VAR
UNSIGNED16
RW
Yes
UNSIGNED16
0
ms
13
Object function:
When the difference (absolute value) between the target position (PP mode: OD 607Ah) and
the position actual value (OD 6064h) is within the range set in OD 6067h (Position window),
and the duration of this condition is longer than the time set in OD 6068h (Position window
time), OD 6041h [Bit 10] (Target reached) is output.
Position window (6067h)
Position window time (6068h)
Target reached
(6041h [Bit 10])
Timer
PP mode
Target position
(607Ah)
+
Window
comparator
-
Position actual value (6064h)
Object 606Bh: Velocity demand value
Index
Name
Object code
Data type
Access
PDO mapping
Setting range
Unit
606Bh
Velocity demand value
VAR
INTEGER32
RO
Yes
INTEGER32
0.1 rpm
Object function:
The velocity demand value is a command generated by the speed trajectory generator and
filtered by the command filter of the drive. This object only works in Profile Velocity mode and
Cyclic Synchronous Velocity mode.