Object 6067h: Position window
Index
Name
Object code
Data type
Access
PDO mapping
Setting range
Default
Unit
6067h
Position window
VAR
UNSIGNED32
RW
Yes
UNSIGNED32
100
PUU
Object function:
When the difference (absolute value) between the target position (PP mode: OD 607Ah) and
the position actual value (OD 6064h) is within the range set in OD 6067h (Position window),
and the duration of this condition is longer than the time set in OD 6068h (Position window
time), OD 6041h [Bit 10] (Target reached) is output.
Accepted position range
Position window
Position window
Position not reached
Position reached
Position not reached
Position
Target position
Position window (6067h)
Position window time (6068h)
Target reached
(6041h [Bit 10])
Timer
PP mode
Target position
(607Ah)
+
Window
comparator
-
Position actual value (6064h)