CANopen Mode
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
12
Object 60FDh: Digital inputs
Index
Name
Object code
Data type
Access
PDO mapping
Setting range
Default
Unit
60FDh
Digital inputs
VAR
UNSIGNED32
RO
Yes
UNSIGNED32
0
-
Object function:
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Bit
Bit 0
Bit 1
Bit 2
Bit 3 - Bit 15
Function
Negative limit signal
Positive limit signal
Homing signal
Reserved
Object 60FEh: Digital outputs
Index
Name
Object code
Data type
Access
60FEh
Digital outputs
ARRAY
UNSIGNED32
RW
Sub-Index
Description
Data type
Access
PDO mapping
Setting range
Default
0
Number of sub-index
UNSIGNED8
RO
Yes
2
2
12-92