Send Quote Requests to info@automatedpt.com
CANopen Mode
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
12
Object 6067h: Position window
Index
Name
Object code
Data type
Access
PDO mapping
Setting range
Default
Unit
6067h
Position window
VAR
UNSIGNED32
RW
Yes
UNSIGNED32
100
PUU
Object function:
When the difference (absolute value) between the position command (PP mode: OD 607Ah;
IP mode: OD 60C1h) and the position actual value (OD 6064h) is within the range set in
OD 6067h (Position window), and the duration of this condition is longer than the time set in
OD 6068h (Position window time), OD 6041h [Bit 10] (Target reached) is output.
Accepted position range
Position window
Position window
Position
Position not reached
Position reached
Position not reached
Target position
Position window (6067h)
Position window time (6068h)
PP mode
Target position
(607Ah)
IP mode
Interpolation data
record (60C1h)
Target reached (6041h [Bit 10])
Timer
+
Window
comparator
-
Position actual value
(6064h)
12-62
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com