CANopen Mode
Object 6064h: Position actual value (PUU)
Index
Name
Object code
Data type
Access
PDO mapping
Setting range
Default
Unit
6064h
Position actual value
VAR
INTEGER32
RO
Yes
INTEGER32
0
PUU
Object 6065h: Following error window
Index
Name
Object code
Data type
Access
PDO mapping
Setting range
Default
Unit
6065h
Following error window
VAR
UNSIGNED32
RW
Yes
UNSIGNED32
50331648
PUU
Object function:
When the following error actual value (OD 60F4h) exceeds this setting range, AL009
(Excessive deviation of Position command) is triggered.
12
Accepted following error
Following error
window
Following error
window
Following error
No following error
Following error
Target position
Note: when P3.012.Z is set to 1, the non-volatile setting for this object is enabled.
Position