CANopen Mode
Object function:
The transmission type setting is as follows:
Setting value
00h (0)
01h - F0h (1 - 240)
F1h - FBh (241 - 251)
FCh (252)
FDh (253)
FEh (254)
FFh (255)
Cyclic
V
Acyclic
V
Transmission type
Synchronous Asynchronous
V
V
Reserved
V
V
V
V
RTR only
V
V
12
Sub-index
Description
Data type
Access
PDO mapping
Setting range
Default
3
Inhibit time
UNSIGNED16
RW
No
UNSIGNED16
0
Sub-index
Description
Data type
Access
PDO mapping
Setting range
Default
4
Reserved
UNSIGNED8
RW
No
UNSIGNED8
0
Sub-index
Description
Data type
Access
PDO mapping
Setting range
Default
5
Event timer
UNSIGNED16
RW
No
0: not in use
UNSIGNED16
0