[ERROR_CODE] 10000_MODULE=Error 10000_TYPE=Communication 10000_RESUME=Abnormal pass parameter transfer. 10000_REASON=Option 1: Mismatch between the UV Flatbed Controller version and the mainboard program version.###Option 2: Communication error between the UV Flatbed Controller and the mainboard program. 10000_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###3. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10001_MODULE=Error 10001_TYPE=Communication 10001_RESUME=Failed to turn off the flush. 10001_REASON=Option 1: The optical fiber connection between the mainboard and the head board failed.###Option 2: The optical fiber module of the mainboard or the head board is abnormal.###Option 3: The power of head board is abnormal. 10001_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10002_MODULE=Error 10002_TYPE=Communication 10002_RESUME=Failed to load the system parameters. 10002_REASON=Option 1: Mismatch between the UV Flatbed Controller version and the mainboard program version.###Option 2: Communication error between the UV Flatbed Controller and the mainboard program. 10002_SOLUTION=1. check the software version information and confirm the first four digits are the same as the mainboard program version.###2. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###3. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10003_MODULE=Error 10003_TYPE=Communication 10003_RESUME=Failed to reset the head board. 10003_REASON=Option 1: Communication error between the mainboard and the head board. 10003_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10004_MODULE=Error 10004_TYPE=Communication 10004_RESUME=Failed to upgrade. 10004_REASON=Option 1: Mismatch between the UV Flatbed Controller version and the mainboard program version.###Option 2: Upgraded file incorrect or corrupted.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 10004_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###3. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10005_MODULE=Error 10005_TYPE=Communication 10005_RESUME=Failed to upgrade the head board. 10005_REASON=Option 1: Communication error between the mainboard and the head board. 10005_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10006_MODULE=Error 10006_TYPE=Communication 10006_RESUME=Failed to print. (Failed to set the ignition signal.) 10006_REASON=Option 1: The power of the head board is abnormal.###Option 2: Communication error between the mainboard and head board. 10006_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10007_MODULE=Error 10007_TYPE=Communication 10007_RESUME=The optical fiber connection between the mainboard and the head board failed. 10007_REASON=Option 1: The optical fiber connection between the mainboard and the head board failed.###Option 2: The optical fiber module of the mainboard or head board is abnormal.###Option 3: The power of the head board is abnormal. 10007_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10008_MODULE=Error 10008_TYPE=Communication 10008_RESUME=Failed to initialize the head board. 10008_REASON=Option 1: Communication error between the mainboard and the head board.###Option 2:Firmware configuration incompatible with the head board.###Option 3: Mismatch between the versions of the mainboard program and the head board microcontrollers. 10008_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10009_MODULE=Error 10009_TYPE=Communication 10009_RESUME=Failed to set the waveform parameters. 10009_REASON=Option 1: The optical fiber connection between the mainboard and the head board failed.###Option 2: The optical fiber module of the mainboard or the head board is abnormal###Option 3: Head board run issue and indicator tower light calls error.###Option 4: Mismatch between the firmware configuration and the head board.###Option 5: Mismatch between the firmware configuration and the head board logic version.###Option 6: Mismatch between the mainboard program version and the head board logic version.### 10009_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10010_MODULE=Error 10010_TYPE=Communication 10010_RESUME=Communication issue between the mainboard and the extension board. (Serial port data reception issue.) 10010_REASON=Option 1: Extension board connection issue. 10010_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10011_MODULE=Error 10011_TYPE=Communication 10011_RESUME=Failed to load the data, no packet received. 10011_REASON=Option 1: Communication error between the UV Flatbed Controller and the mainboard program.###Option 2: Mainboard run issue.###Option 3: USB communication mode set error.###Option 4: Incorrect software configuration. 10011_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10012_MODULE=Error 10012_TYPE=Communication 10012_RESUME=Failed to start printing.###(Communication issue between the UV Flatbed Controller and the mainboard.) 10012_REASON=Option 1: Communication error between the UV Flatbed Controller and the mainboard program.###Option 2: Mainboard run issue. 10012_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###3. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10014_MODULE=Error 10014_TYPE=Communication 10014_RESUME=Failed to obtain voltage regulation information. 10014_REASON=Option 1: Communication error between the UV Flatbed Controller and the mainboard program.###Option 2: Mainboard run issue. 10014_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###3. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10015_MODULE=Error 10015_TYPE=Communication 10015_RESUME=Failed to print. (Failed to send the print data.) 10015_REASON=Option 1: Communication error between the UV Flatbed Controller and the mainboard program.###Option 2: Mainboard run issue. 10015_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###3. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10016_MODULE=Error 10016_TYPE=Communication 10016_RESUME=Failed to print. (Failed to send the print information.) 10016_REASON=Option 1: Communication error between the UV Flatbed Controller and the mainboard program.###Option 2: Mainboard run issue. 10016_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###3. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10017_MODULE=Error 10017_TYPE=Communication 10017_RESUME=Timeout when waiting to obtain the motor grating resolution or calculating the action start of the X gear ratio. 10017_REASON=Option 1: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 2: Communication error between the UV Flatbed Controller and the mainboard program.###Option 3: Mainboard run issue. 10017_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10018_MODULE=Error 10018_TYPE=Communication 10018_RESUME=Timeout when waiting to obtain the motor grating resolution or calculating the action end of the X gear ratio. 10018_REASON=Option 1: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 2: Communication error between the UV Flatbed Controller and the mainboard program.###Option 3: Mainboard run issue. 10018_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10019_MODULE=Error 10019_TYPE=Communication 10019_RESUME=System parameter issue. (Failed to get the X white margin position.) 10019_REASON=Option 1: Communication error between the UV Flatbed Controller and the mainboard program.###Option 2: Mainboard run issue. 10019_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###3. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10020_MODULE=Error 10020_TYPE=Communication 10020_RESUME=System parameter issue. (Failed to get the X gear ratio.) 10020_REASON=Option 1: Communication error between the UV Flatbed Controller and the mainboard program.###Option 2: Mainboard run issue. 10020_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###3. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10021_MODULE=Error 10021_TYPE=Communication 10021_RESUME=Failed to print. (Timeout when waiting for the print action to be executed.) 10021_REASON=Option 1: Communication error between the UV Flatbed Controller and the mainboard program.###Option 2: Mainboard run issue.###Option 3: The firmware configuration or firmware parameters are incorrect or corrupted. 10021_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###3. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 10022_MODULE=Error 10022_TYPE=Communication 10022_RESUME=Failed to print. (Timeout when waiting for the printer to enter the print status.) 10022_REASON=Option 1: Print initialization execution is abnormal.###Option 2: Communication error between the UV Flatbed Controller and the mainboard program.###Option 3: Mainboard run issue.###Option 4: The firmware configuration or the firmware parameters are incorrect or corrupted. 10022_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###3. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11000_MODULE=Error 11000_TYPE=Parameter 11000_RESUME=Failed to obtain the logic printhead ID. 11000_REASON=Option 1: The firmware parameters or firmware configuration is incorrect. 11000_SOLUTION=Take note of the error code and contact your service representative. 11001_MODULE=Error 11001_TYPE=Parameter 11001_RESUME=Failed to obtain the physical printhead ID. 11001_REASON=Option 1: The firmware parameters or firmware configuration is incorrect. 11001_SOLUTION=Take note of the error code and contact your service representative. 11002_MODULE=Error 11002_TYPE=Parameter 11002_RESUME=Failed to detect a physical printhead. 11002_REASON=Option 1: The firmware parameters or firmware configuration is incorrect. 11002_SOLUTION=Take note of the error code and contact your service representative. 11003_MODULE=Error 11003_TYPE=Parameter 11003_RESUME=Failed to analyze the parameters when executing a combined operation. 11003_REASON=Option 1: The firmware parameters or firmware configuration is incorrect. 11003_SOLUTION=Take note of the error code and contact your service representative. 11004_MODULE=Error 11004_TYPE=Parameter 11004_RESUME=The current execution of the combined operation is unavailable. 11004_REASON=Option 1: The firmware parameters or firmware configuration is incorrect. 11004_SOLUTION=Take note of the error code and contact your service representative. 11010_MODULE=Error 11010_TYPE=Parameter 11010_RESUME=Failed to save the system parameters. 11010_REASON=Option 1: The saved parameters are not native parameters. 11010_SOLUTION=Take note of the error code and contact your service representative. 11012_MODULE=Error 11012_TYPE=Parameter 11012_RESUME=Failed to print. (Machine mode mismatch.) 11012_REASON=Option 1: The firmware configuration is incorrect or corrupted. 11012_SOLUTION=Take note of the error code and contact your service representative. 11013_MODULE=Error 11013_TYPE=Parameter 11013_RESUME=Failed to print. (The mainboard does not support the head board.) 11013_REASON=Option 1: Head board connection issue.###Option 2: The mainboard does not support the head board. 11013_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11022_MODULE=Error 11022_TYPE=Parameter 11022_RESUME=The current waveform data is inconsistent with the printhead type. 11022_REASON=Option 1: Waveform data is incorrect or corrupted.###Option 2: Firmware parameter is incorrect or corrupted.###Option 3: Mismatch between the system waveform data and the current head board. 11022_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11023_MODULE=Error 11023_TYPE=Parameter 11023_RESUME=Failed to obtain the printheads layout management module. 11023_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11023_SOLUTION=Take note of the error code and contact your service representative. 11024_MODULE=Error 11024_TYPE=Parameter 11024_RESUME=Failed to obtain the media management module. 11024_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11024_SOLUTION=Take note of the error code and contact your service representative. 11025_MODULE=Error 11025_TYPE=Parameter 11025_RESUME=Failed to obtain the horizontal print resolution management module. 11025_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11025_SOLUTION=Take note of the error code and contact your service representative. 11026_MODULE=Error 11026_TYPE=Parameter 11026_RESUME=Failed to obtain the overall parameter management module. 11026_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11026_SOLUTION=Take note of the error code and contact your service representative. 11027_MODULE=Error 11027_TYPE=Parameter 11027_RESUME=Failed to obtain the print mode management module. 11027_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11027_SOLUTION=Take note of the error code and contact your service representative. 11028_MODULE=Error 11028_TYPE=Parameter 11028_RESUME=Failed to obtain the speed management module. 11028_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11028_SOLUTION=Take note of the error code and contact your service representative. 11029_MODULE=Error 11029_TYPE=Parameter 11029_RESUME=Failed to obtain the board card encryption module. 11029_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11029_SOLUTION=Take note of the error code and contact your service representative. 11030_MODULE=Error 11030_TYPE=Parameter 11030_RESUME=Failed to obtain the printhead management module. 11030_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11030_SOLUTION=Take note of the error code and contact your service representative. 11032_MODULE=Error 11032_TYPE=Parameter 11032_RESUME=The head ID could not be registered. 11032_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11032_SOLUTION=Take note of the error code and contact your service representative. 11033_MODULE=Error 11033_TYPE=Parameter 11033_RESUME=The required horizontal print resolution index is unavailable. 11033_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11033_SOLUTION=Take note of the error code and contact your service representative. 11034_MODULE=Error 11034_TYPE=Parameter 11034_RESUME=The required speed index is unavailable. 11034_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11034_SOLUTION=Take note of the error code and contact your service representative. 11035_MODULE=Error 11035_TYPE=Parameter 11035_RESUME=The required media index is unavailable. 11035_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11035_SOLUTION=Take note of the error code and contact your service representative. 11036_MODULE=Error 11036_TYPE=Parameter 11036_RESUME=The required printhead cleaning index is unavailable. 11036_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11036_SOLUTION=Take note of the error code and contact your service representative. 11037_MODULE=Error 11037_TYPE=Parameter 11037_RESUME=The required printhead cleaning mode index is unavailable. 11037_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11037_SOLUTION=Take note of the error code and contact your service representative. 11038_MODULE=Error 11038_TYPE=Parameter 11038_RESUME=The required printhead ink loading index is unavailable. 11038_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11038_SOLUTION=Take note of the error code and contact your service representative. 11039_MODULE=Error 11039_TYPE=Parameter 11039_RESUME=The required logic head layout index is unavailable. 11039_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11039_SOLUTION=Take note of the error code and contact your service representative. 11040_MODULE=Error 11040_TYPE=Parameter 11040_RESUME=Mismatch between the horizontal and the vertical resolution of the PRN file. 11040_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11040_SOLUTION=Take note of the error code and contact your service representative. 11041_MODULE=Error 11041_TYPE=Parameter 11041_RESUME=Failed to find the logic head. 11041_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11041_SOLUTION=Take note of the error code and contact your service representative. 11042_MODULE=Error 11042_TYPE=Parameter 11042_RESUME=Failed to find the logic channel. 11042_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11042_SOLUTION=Take note of the error code and contact your service representative. 11043_MODULE=Error 11043_TYPE=Parameter 11043_RESUME=Failed to find a physical channel. 11043_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11043_SOLUTION=Take note of the error code and contact your service representative. 11044_MODULE=Error 11044_TYPE=Parameter 11044_RESUME=Failed to find ink. 11044_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11044_SOLUTION=Take note of the error code and contact your service representative. 11045_MODULE=Error 11045_TYPE=Parameter 11045_RESUME=Incorrect PRN color. (Does not correspond to the ink color.) 11045_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11045_SOLUTION=Take note of the error code and contact your service representative. 11047_MODULE=Error 11047_TYPE=Parameter 11047_RESUME=Invalid nozzle range error. 11047_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11047_SOLUTION=Take note of the error code and contact your service representative. 11048_MODULE=Error 11048_TYPE=Parameter 11048_RESUME=ID error for the clogged head. 11048_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11048_SOLUTION=Take note of the error code and contact your service representative. 11049_MODULE=Error 11049_TYPE=Parameter 11049_RESUME=Hardware fill parameter error. 11049_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11049_SOLUTION=Take note of the error code and contact your service representative. 11050_MODULE=Error 11050_TYPE=Parameter 11050_RESUME=Hardware fill cache error. 11050_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11050_SOLUTION=Take note of the error code and contact your service representative. 11051_MODULE=Error 11051_TYPE=Parameter 11051_RESUME=Print task type error. 11051_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11051_SOLUTION=Take note of the error code and contact your service representative. 11052_MODULE=Error 11052_TYPE=Parameter 11052_RESUME=Board ID & Board Channel ID error. 11052_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11052_SOLUTION=Take note of the error code and contact your service representative. 11053_MODULE=Error 11053_TYPE=Parameter 11053_RESUME=Physical channel properties ID & Exist error. 11053_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration. 11053_SOLUTION=Take note of the error code and contact your service representative. 11055_MODULE=Error 11055_TYPE=Parameter 11055_RESUME=Failed to obtain the layout management. 11055_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11055_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11056_MODULE=Error 11056_TYPE=Parameter 11056_RESUME=Failed to obtain the selected printhead parameters. 11056_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11056_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11057_MODULE=Error 11057_TYPE=Parameter 11057_RESUME=Failed to obtain the selected printhead parameters. (Physical layout) 11057_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11057_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11058_MODULE=Error 11058_TYPE=Parameter 11058_RESUME=Failed to obtain the selected printhead parameters. (Logic layout) 11058_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11058_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11059_MODULE=Error 11059_TYPE=Parameter 11059_RESUME=Failed to obtain the Print mode parameters. (Data processing mode.) 11059_REASON=Option 1: The resolution, colors or dotting of this task is not supported.###Option 2: The firmware configuration or firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is mismatched with the firmware parameters.###Option 4: The UV Flatbed Controller version is mismatched with the mainboard program version. 11059_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11060_MODULE=Error 11060_TYPE=Parameter 11060_RESUME=Failed to obtain the calibration chart parameters. 11060_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11060_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11061_MODULE=Error 11061_TYPE=Parameter 11061_RESUME=Failed to obtain the calibration chart parameters. (Calibration template.) 11061_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11061_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11062_MODULE=Error 11062_TYPE=Parameter 11062_RESUME=Failed to obtain the physical clogged nozzle channel parameters. 11062_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11062_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11063_MODULE=Error 11063_TYPE=Parameter 11063_RESUME=Failed to obtain the physical channel status parameters. (Channel closed.) 11063_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11063_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11064_MODULE=Error 11064_TYPE=Parameter 11064_RESUME=Failed to obtain the default waveform. 11064_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11064_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11065_MODULE=Error 11065_TYPE=Parameter 11065_RESUME=Failed to obtain the print speed. 11065_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11065_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11066_MODULE=Error 11066_TYPE=Parameter 11066_RESUME=Failed to obtain the horizontal print resolution. 11066_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11066_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11067_MODULE=Error 11067_TYPE=Parameter 11067_RESUME=Failed to obtain the calibration parameters. (Left side standard chromatic.) 11067_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11067_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11068_MODULE=Error 11068_TYPE=Parameter 11068_RESUME=Failed to obtain the calibration parameters. (Right side standard chromatic.) 11068_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11068_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11069_MODULE=Error 11069_TYPE=Parameter 11069_RESUME=Failed to obtain the calibration parameters. (Left side chromatic offset.) 11069_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11069_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11070_MODULE=Error 11070_TYPE=Parameter 11070_RESUME=Failed to obtain the calibration parameters. (Right side chromatic offset.) 11070_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11070_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11071_MODULE=Error 11071_TYPE=Parameter 11071_RESUME=Failed to obtain the calibration parameters. (Left side printhead horizontal spacing.) 11071_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11071_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11072_MODULE=Error 11072_TYPE=Parameter 11072_RESUME=Failed to obtain the calibration parameters. (Right side printhead horizontal spacing.) 11072_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11072_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11073_MODULE=Error 11073_TYPE=Parameter 11073_RESUME=Failed to obtain the calibration parameters. (Right side printhead vertical spacing.) 11073_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11073_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11074_MODULE=Error 11074_TYPE=Parameter 11074_RESUME=Failed to calculate the maximum color chromatic offset. 11074_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11074_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11075_MODULE=Error 11075_TYPE=Parameter 11075_RESUME=Failed to obtain the white margin parameters. 11075_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11075_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11076_MODULE=Error 11076_TYPE=Parameter 11076_RESUME=Failed to set the multiple ink parameters. 11076_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11076_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11077_MODULE=Error 11077_TYPE=Parameter 11077_RESUME=Failed to obtain the channel control parameters. 11077_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11077_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11081_MODULE=Error 11081_TYPE=Parameter 11081_RESUME=Failed to print. (System parameters issue.) 11081_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11081_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11082_MODULE=Error 11082_TYPE=Parameter 11082_RESUME=Layout configuration error. (Physical printhead cannot be found.) 11082_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11082_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11083_MODULE=Error 11083_TYPE=Parameter 11083_RESUME=Layout configuration error. (Physical channel cannot be found.) 11083_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11083_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11084_MODULE=Error 11084_TYPE=Parameter 11084_RESUME=Layout configuration error. (Designated physical channel cannot be found.) 11084_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11084_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11085_MODULE=Error 11085_TYPE=Parameter 11085_RESUME=Logic layout configuration error. (Physical channel cannot be found.) 11085_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11085_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11086_MODULE=Error 11086_TYPE=Parameter 11086_RESUME=Logic layout configuration error. (Designated physical channel cannot be found.) 11086_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11086_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11087_MODULE=Error 11087_TYPE=Parameter 11087_RESUME=Failed to obtain the current physical layout. 11087_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11087_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11088_MODULE=Error 11088_TYPE=Parameter 11088_RESUME=Failed to obtain the calibration chart information. 11088_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11088_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11089_MODULE=Error 11089_TYPE=Parameter 11089_RESUME=Failed to obtain the calibration print mode. 11089_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11089_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11090_MODULE=Error 11090_TYPE=Parameter 11090_RESUME=Failed to obtain the calibration print speed. 11090_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11090_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11091_MODULE=Error 11091_TYPE=Parameter 11091_RESUME=Failed to obtain the calibration print waveform. 11091_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11091_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11092_MODULE=Error 11092_TYPE=Parameter 11092_RESUME=Failed to add the calibration task. 11092_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11092_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11093_MODULE=Error 11093_TYPE=Parameter 11093_RESUME=Failed to obtain the calibration chart information. 11093_REASON=Option 1: The firmware parameters or firmware configuration is incorrect or corrupted.###Option 2: Mismatch between the firmware parameters or the firmware configuration.###Option 3: Mismatch between the UV Flatbed Controller version and the mainboard program version. 11093_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 11094_MODULE=Error 11094_TYPE=Parameter 11094_RESUME=Waveform authorization failed. 11094_REASON=Option 1: Waveform file error 11094_SOLUTION=Take note of the error code and contact your service representative. 11095_MODULE=Error 11095_TYPE=Parameter 11095_RESUME=Waveform authentication failed. 11095_REASON=Option 1: Waveform file error 11095_SOLUTION=Take note of the error code and contact your service representative. 12000_MODULE=Error 12000_TYPE=Hardware 12000_RESUME=The mainboard failed to save the parameters. 12000_REASON=Option 1: Mainboard Flash may be destroyed###Option 2: Mainboard Flash is out of memory 12000_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 12001_MODULE=Error 12001_TYPE=Hardware 12001_RESUME=The mainboard DO setting failed. 12001_REASON=Option 1:The output interface is not connected to external device. (PC) 12001_SOLUTION=1. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 12003_MODULE=Error 12003_TYPE=Hardware 12003_RESUME=Carriage scale issue. 12003_REASON=Option 1: CR scale reading issue. 12003_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 12004_MODULE=Error 12004_TYPE=Hardware 12004_RESUME=A paper shortage was detected during printing 12004_REASON=Option 1: paper out 12004_SOLUTION=1.Please supplement materials。###2.Please check whether the missing paper sensor is normal.###3.Check whether the cable connection to the sensor is correct. 12005_MODULE=Error 12005_TYPE=Hardware 12005_RESUME=The air box is full of liquid. 12005_REASON=Option 1: Air box full. 12005_SOLUTION=Take note of the error code and contact your service representative. 12006_MODULE=Error 12006_TYPE=Hardware 12006_RESUME=Sub-tank ink low. 12006_REASON=Option 1: Sub-ink tank ink low 12006_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12007_MODULE=Error 12007_TYPE=Hardware 12007_RESUME=A system issue triggered an emergency stop. 12007_REASON=Option 1: An emergency stop signal was triggered. 12007_SOLUTION=1. Check if an emergency stop was triggered.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 12008_MODULE=Error 12008_TYPE=Hardware 12008_RESUME=A system issue triggered an anti-collision signal. 12008_REASON=Option 1: An anti-collision signal was triggered. 12008_SOLUTION=1. Check if an emergency stop was triggered.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 12009_MODULE=Error 12009_TYPE=Hardware 12009_RESUME=Main tank ink low. 12009_REASON=Option 1: Main ink tank ink low. 12009_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12010_MODULE=Error 12010_TYPE=Hardware 12010_RESUME=Waste ink detected. 12010_REASON=Option 1: Waste ink detected. 12010_SOLUTION=Take note of the error code and contact your service representative. 12500_MODULE=Error 12500_TYPE=Hardware 12500_RESUME=Cyan sub-tank ink low. 12500_REASON=Option 1: The Cyan ink sub-tank level is low.###Option 2: The floating ball liquid sensor is broken. 12500_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12501_MODULE=Error 12501_TYPE=Hardware 12501_RESUME=Magenta sub-tank ink low. 12501_REASON=Option 1: The Magenta ink sub-tank level is low.###Option 2: The floating ball liquid sensor is broken. 12501_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12502_MODULE=Error 12502_TYPE=Hardware 12502_RESUME=Yellow sub-tank ink low. 12502_REASON=Option 1: The Yellow ink sub-tank level is low.###Option 2: The floating ball liquid sensor is broken. 12502_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12503_MODULE=Error 12503_TYPE=Hardware 12503_RESUME=Black sub-tank ink low. 12503_REASON=Option 1: The Black ink sub-tank level is low.###Option 2: The floating ball liquid sensor is broken. 12503_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12504_MODULE=Error 12504_TYPE=Hardware 12504_RESUME=Light-cyan sub-tank ink low. 12504_REASON=Option 1: The Light-cyan ink sub-tank level is low.###Option 2: The floating ball liquid sensor is broken. 12504_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12505_MODULE=Error 12505_TYPE=Hardware 12505_RESUME=Light-magenta sub-tank ink low. 12505_REASON=Option 1: The Light-magenta ink sub-tank level is low .###Option 2: The floating ball liquid sensor is broken. 12505_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12506_MODULE=Error 12506_TYPE=Hardware 12506_RESUME=Red sub-tank ink low. 12506_REASON=Option 1: The Red ink sub-tank level is low.###Option 2: The floating ball liquid sensor is broken. 12506_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12507_MODULE=Error 12507_TYPE=Hardware 12507_RESUME=Grey sub-tank ink low. 12507_REASON=Option 1: The Grey ink sub-tank level is low.###Option 2: The floating ball liquid sensor is broken. 12507_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12508_MODULE=Error 12508_TYPE=Hardware 12508_RESUME=Color safety bottle issue. 12508_REASON=Option 1: The color safety bottle is full.###Option 2: The floating ball liquid sensor is broken. 12508_SOLUTION=Take note of the error code and contact your service representative. 12509_MODULE=Error 12509_TYPE=Hardware 12509_RESUME=White ink safety bottle issue. 12509_REASON=Option 1: The white ink safety bottle is full.###Option 2: The floating ball liquid sensor is broken. 12509_SOLUTION=Take note of the error code and contact your service representative. 12510_MODULE=Error 12510_TYPE=Hardware 12510_RESUME=Cyan main tank ink low. 12510_REASON=Option 1: The Cyan main tank ink level is low.###Option 2: The floating ball liquid sensor is broken. 12510_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12511_MODULE=Error 12511_TYPE=Hardware 12511_RESUME=Magenta main tank ink low. 12511_REASON=Option 1: The Magenta main tank ink level is low.###Option 2: The floating ball liquid sensor is broken. 12511_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12512_MODULE=Error 12512_TYPE=Hardware 12512_RESUME=Yellow main tank ink low. 12512_REASON=Option 1: The Yellow main tank ink level is low.###Option 2: The floating ball liquid sensor is broken. 12512_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12513_MODULE=Error 12513_TYPE=Hardware 12513_RESUME=Black main tank ink low. 12513_REASON=Option 1: The Black main tank ink level is low.###Option 2: The floating ball liquid sensor is broken. 12513_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12514_MODULE=Error 12514_TYPE=Hardware 12514_RESUME=Light-cyan main tank ink low. 12514_REASON=Option 1: The Light-cyan main tank ink level is low.###Option 2: The floating ball liquid sensor is broken. 12514_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12515_MODULE=Error 12515_TYPE=Hardware 12515_RESUME=Light-magenta main tank ink low. 12515_REASON=Option 1: The Light-magenta main tank ink level is low.###Option 2: The floating ball liquid sensor is broken. 12515_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12516_MODULE=Error 12516_TYPE=Hardware 12516_RESUME=Red main tank ink low. 12516_REASON=Option 1: The Red main tank ink level is low.###Option 2: The floating ball liquid sensor is broken. 12516_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12517_MODULE=Error 12517_TYPE=Hardware 12517_RESUME=Grey main tank ink low. 12517_REASON=Option 1: The Grey main tank ink level is low.###Option 2: The floating ball liquid sensor is broken. 12517_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12518_MODULE=Error 12518_TYPE=Hardware 12518_RESUME=White main tank ink low. 12518_REASON=Option 1: The White main tank ink level is low.###Option 2: The floating ball liquid sensor is broken. 12518_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12519_MODULE=Error 12519_TYPE=Hardware 12519_RESUME=Varnish main tank ink low. 12519_REASON=Option 1: The Varnish main tank ink level is low.###Option 2: The floating ball liquid sensor is broken. 12519_SOLUTION=1. Charge ink if the ink is low in one of the main ink tanks.###2. Press the "Ink Reset" button on the front panel of the printer to send ink from the main tank to the sub tank.###3. If the error keeps reoccurring, take note of the error code and contact your service representative. 12520_MODULE=Error 12520_TYPE=Hardware 12520_RESUME=Wetting lower limit issue. 12520_REASON=Option 1: Abnormal connection between the mainboard and the limit connection line.###Option 2: Limit sensor abnormal.###Option 3: Link error between the limit input signal and the board signal. 12520_SOLUTION=Take note of the error code and contact your service representative. 12521_MODULE=Error 12521_TYPE=Hardware 12521_RESUME=Wetting upper limit issue. 12521_REASON=Option 1: Abnormal connection between the mainboard and the limit connection line.###Option 2: Limit sensor abnormal.###Option 3: Link error between the limit input signal and the board signal. 12521_SOLUTION=Take note of the error code and contact your service representative. 12522_MODULE=Error 12522_TYPE=Hardware 12522_RESUME=Cleaning origin limit issue. 12522_REASON=Option 1: Abnormal connection between the mainboard and the limit connection line.###Option 2: Limit sensor abnormal.###Option 3: Link error between the limit input signal and the board signal. 12522_SOLUTION=Take note of the error code and contact your service representative. 12523_MODULE=Error 12523_TYPE=Hardware 12523_RESUME=Cleaning end limit issue. 12523_REASON=Option 1: Abnormal connection between the mainboard and the limit connection line.###Option 2: Limit sensor abnormal.###Option 3: Link error between the limit input signal and the board signal. 12523_SOLUTION=Take note of the error code and contact your service representative. 12532_MODULE =Error 12532_TYPE=Hardware 12532_RESUME =Failed to execute motor movement 12532_REASON =Option 1. Motor connection abnormal ###Option 2. Motor encoder feedback abnormal 12532_SOLUTION = 1. Check the connection port of the motor to ensure good contact ### 2. Check the encoder feedback connection or signal polarity 12542_MODULE=Error 12542_TYPE=Hardware 12542_RESUME=Abnormal 42V power input. 12542_REASON=Option 1: FFC cables connection issue. ###Option 2: Ink on the FFC cable or the cables plugs. ###Option 3: Short circuit between the board power supply and the printhead power supply or abnormal voltage. 12542_SOLUTION=Take note of the error code and contact your service representative. 12543_MODULE=Error 12543_TYPE=Hardware 12543_RESUME=Abnormal nozzle VH power supply. 12543_REASON=Option 1: FFC cables connection issue. ###Option 2: Ink on the FFC cable or the cables plugs. ###Option 3: Short circuit between the board power supply and the printhead power supply or abnormal voltage. 12543_SOLUTION=Take note of the error code and contact your service representative. 12544_MODULE=Error 12544_TYPE=Hardware 12544_RESUME=Abnormal nozzle VDD. 12544_REASON=Option 1: FFC cables connection issue. ###Option 2: Ink on the FFC cable or the cables plugs. ###Option 3: Short circuit between the board power supply and the printhead power supply or abnormal voltage. 12544_SOLUTION=Take note of the error code and contact your service representative. 12545_MODULE=Error 12545_TYPE=Hardware 12545_RESUME=Current overload on the VH power supply and 42V power amplifier. 12545_REASON=Option 1: FFC cables connection issue. ###Option 2: Ink on the FFC cable or the cables plugs. ###Option 3: Short circuit between the board power supply and the printhead power supply or abnormal voltage. 12545_SOLUTION=Take note of the error code and contact your service representative. 12546_MODULE=Error 12546_TYPE=Hardware 12546_RESUME=Abnormal JCOM. 12546_REASON=Option 1: FFC cables connection issue. ###Option 2: Ink on the FFC cable or the cables plugs. ###Option 3: Short circuit between the board power supply and the printhead power supply or abnormal voltage. 12546_SOLUTION=Take note of the error code and contact your service representative. 12547_MODULE=Error 12547_TYPE=Hardware 12547_RESUME=FFC Connection Error 12547_REASON=Option 1: FFC (Flexible Flat Cable) connection issue. 12547_SOLUTION=1. Check if there is an FFC disconnected. If there is, re-connect it or call your service representative to do it.###2. Check if the FFC or FFC connector is stained by ink. If it is, replace it or call your service representative to do it.###3. Check if the FFC is not strongly bent or folded. If it is, try to insert again the cable straight or contact your service representative to do it.###4. If the above solutions did not help, please contact your service representative. 12548_MODULE=Error 12548_TYPE=Hardware 12548_RESUME=Abnormal Printhead Temperature 12548_REASON=Option 1: Printhead overheat due to a heavy duty print job.###Option 2: Printhead defect. 12548_SOLUTION=1. The printer will re-start automatically if the head temperature goes down after a 10 seconds cooling pause. Please select if you want to continue or cancel the action.###2. If the same printhead overheat error keeps on occurring for a specific job, try the below actions:### 1) Select a lower speed print mode.### 2) Print in single direction (Uni-D)### 3) Reduce the ink duty of the picture.###3. If the error is still occurring and the above solutions did not help, please re-start the printer and see if the error comes back. If it does, please contact your service representative. 13000_MODULE=Error 13000_TYPE=Software 13000_RESUME=Failed to open the files. 13000_REASON=Option 1: The file not exit.###Option 2: The file is used by another application. 13000_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13001_MODULE=Error 13001_TYPE=Software 13001_RESUME=File format flag error! Failed to open the firmware parameters or the firmware configuration file! 13001_REASON=Option 1: The file format is incorrect.###Option 2: The file data are corrupted. 13001_SOLUTION=Take note of the error code and contact your service representative. 13002_MODULE=Error 13002_TYPE=Software 13002_RESUME=File compatibility number error! Failed to open the firmware parameters or the firmware configuration file! 13002_REASON=Option 1: The file format is incorrect.###Option 2: The file data are corrupted. 13002_SOLUTION=Take note of the error code and contact your service representative. 13003_MODULE=Error 13003_TYPE=Software 13003_RESUME=File version error! Failed to open the firmware parameters or the firmware configuration file! 13003_REASON=Option 1: The file format is incorrect.###Option 2: The file data are corrupted. 13003_SOLUTION=Take note of the error code and contact your service representative. 13004_MODULE=Error 13004_TYPE=Software 13004_RESUME=File data type error! Failed to open the firmware parameters or the firmware configuration file! 13004_REASON=Option 1: The file format is incorrect.###Option 2: The file data are corrupted. 13004_SOLUTION=Take note of the error code and contact your service representative. 13005_MODULE=Error 13005_TYPE=Software 13005_RESUME=Memory access overflow. 13005_REASON=Option 1: Memory access error. 13005_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13006_MODULE=Error 13006_TYPE=Software 13006_RESUME=Out of memory. 13006_REASON=Option 1: Out of memory. 13006_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13007_MODULE=Error 13007_TYPE=Software 13007_RESUME=Failed to verify MD5 data. 13007_REASON=Option 1: File analysis failed or the file data is corrupted.###Option 2: Mismatch between the software and the mainboard program version. 13007_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13008_MODULE=Error 13008_TYPE=Software 13008_RESUME=Failed to update. (File analysis failed). 13008_REASON=Option 1: File analysis failed or the file data is corrupted.###Option 2: Mismatch between the software and the mainboard program version. 13008_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13009_MODULE=Error 13009_TYPE=Software 13009_RESUME=Failed to read the Flash A area. 13009_REASON=Option 1: Mainboard parameters are corrupted or abnormal.###Option 2: The mainboard flash may be defective. 13009_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13010_MODULE=Error 13010_TYPE=Software 13010_RESUME=Failed to read the Flash B area. 13010_REASON=Option 1: Mainboard parameters are corrupted or abnormal.###Option 2: The mainboard flash may be defective. 13010_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13011_MODULE=Error 13011_TYPE=Software 13011_RESUME=Flash data analysis failed. 13011_REASON=Option 1: Mainboard parameters are corrupted or abnormal. 13011_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13012_MODULE=Error 13012_TYPE=Software 13012_RESUME=Failed to load the flash and enter the reset mode, please upgrade the mainboard program or reset the Flash. 13012_REASON=Option 1: Mainboard parameters are not initialized. 13012_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13013_MODULE=Error 13013_TYPE=Software 13013_RESUME=Failed to execute the system initialization. 13013_REASON=Option 1: The firmware configuration is incorrect or corrupted.###Option 2: The firmware parameters are incorrect or corrupted.###Option 3: The mainboard and the head board are connect improperly.###Option 4: The limit switches are invalid or connected improperly.###Option 5: Motor or servo movement issue.###Option 6: A slow carriage movement speed caused a timeout. 13013_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13015_MODULE=Error 13015_TYPE=Software 13015_RESUME=Failed to read the clock. 13015_REASON=Option 1. Clock chip issue or mainboard time setting issue. 13015_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13016_MODULE=Error 13016_TYPE=Software 13016_RESUME=Failed to set the clock. 13016_REASON=Option 1. Clock chip issue or mainboard time setting issue. 13016_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13018_MODULE=Error 13018_TYPE=Software 13018_RESUME=Combined operation is disabled. 13018_REASON=Option 1: The system is busy executing another action.###Option 2: This action cannot be executed in the current system status. 13018_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13019_MODULE=Error 13019_TYPE=Software 13019_RESUME=Combined operation is disabled. 13019_REASON=Option 1: The system is busy executing another action.###Option 2: This action cannot be executed in the current system status. 13019_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13020_MODULE=Error 13020_TYPE=Software 13020_RESUME=Signal height test failed. 13020_REASON=Option 1: The micro-switch broke and can not detect the micro-switch signal.###Option 2: Z motor or driver is defective.###Option 3: A slow motion of the Z axis led to a timeout. 13020_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13021_MODULE=Error 13021_TYPE=Software 13021_RESUME=Gear ratio calibration failed. 13021_REASON=Option 1: The X-axis motor or driver is invalid.###Option 2: A slow X-axis moving speed caused a timeout 13021_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13022_MODULE= Error 13022_TYPE= Software 13022_RESUME= Failed to test paper 13022_REASON= Possible 1. Whether the non-detected area exceeds the print area ### Possible 2. The paper sensor is abnormal 13022_SOLUTION=1. Check whether the non-detected area exceeds the print area ###2. Please check whether the measuring paper sensor is working properly 13023_MODULE= Error 13023_TYPE= Software 13023_RESUME= Abnormal ink stack 13023_REASON= Possible 1. Ink stack motor abnormal ### Possible 2. The ink stack limit is abnormal 13023_SOLUTION=1. Check whether the ink stack motor and ink stack limit are normal 13024_MODULE=Error 13024_TYPE=Software 13024_RESUME=Print initialization action failed. 13024_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13024_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13025_MODULE=Error 13025_TYPE=Software 13025_RESUME=Failed to print. (Failed to execute a pause action.) 13025_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13025_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13026_MODULE=Error 13026_TYPE=Software 13026_RESUME=Failed to print. (System error status issue.) 13026_REASON=Option 1: The system is in error status. 13026_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13027_MODULE=Error 13027_TYPE=Software 13027_RESUME=Failed to print. (System abnormal status issue.) 13027_REASON=Option 1: The system is in abnormal status. 13027_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13028_MODULE=Error 13028_TYPE=Software 13028_RESUME=Failed to print. (Failed to execute an automatic cleaning action.) 13028_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13028_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13029_MODULE=Error 13029_TYPE=Software 13029_RESUME=Failed to print. (Failed to execute a cancel action.) 13029_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13029_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13030_MODULE=Error 13030_TYPE=Software 13030_RESUME=Failed to print. (Failed to execute a continue action.) 13030_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13030_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13031_MODULE=Error 13031_TYPE=Software 13031_RESUME=Failed to print. (Failed to execute a cleaning action.) 13031_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13031_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13032_MODULE=Error 13032_TYPE=Software 13032_RESUME=Failed to print. (Failed to execute a move left action.) 13032_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13032_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13033_MODULE=Error 13033_TYPE=Software 13033_RESUME=Failed to print. (Failed to execute a move right action.) 13033_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13033_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13034_MODULE=Error 13034_TYPE=Software 13034_RESUME=Failed to print. (Failed to execute a move upwards action.) 13034_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13034_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13035_MODULE=Error 13035_TYPE=Software 13035_RESUME=Failed to print. (Failed to execute a move downwards action.) 13035_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13035_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13036_MODULE=Error 13036_TYPE=Software 13036_RESUME=Failed to print. (White jump failed.) 13036_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13036_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13037_MODULE=Error 13037_TYPE=Software 13037_RESUME=Failed to print. (Failed before executing a print pass action.) 13037_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13037_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13038_MODULE=Error 13038_TYPE=Software 13038_RESUME=Failed to print. (Failed when executing a print pass action.) 13038_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13038_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13039_MODULE=Error 13039_TYPE=Software 13039_RESUME=Failed to print. (Failed after executing a print pass action.) 13039_REASON=Option 1: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 2: The connection between the mainboard and the head board is abnormal.###Option 3: Limit switch invalid or connection defect.###Option 4: Motor or servo movement abnormal.###Option 5: Slow carriage movement speed caused a timeout.###Option 6: Mismatch between the mainboard program and the head board logic. 13039_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13041_MODULE=Error 13041_TYPE=Software 13041_RESUME=Failed to print. (Carriage starting position incorrect for the next pass). 13041_REASON=Option 1: Carriage scale issue.###Option 2: Gear ratio issue. 13041_SOLUTION=Take note of the error code and contact your service representative. 13044_MODULE=Error 13044_TYPE=Software 13044_RESUME=Overtime when waiting for the motor to stop. 13044_REASON=Option 1: The parameter time for the firmware configuration is too short. 13044_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13046_MODULE=Error 13046_TYPE=Software 13046_RESUME=Timeout when waiting for a signal stop. 13046_REASON=Option 1: The parameter time for the firmware configuration is too short. 13046_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13047_MODULE=Error 13047_TYPE=Software 13047_RESUME=Failed to print. (The print pass data was unfinished.) 13047_REASON=Option 1: Carriage scale issue.###Option 2: Gear ratio issue.###Option 3: X limit or motor issue.###Option 4: The head board connection is abnormal.###Option 5: The power supply of the head board is abnormal.###Option 6: The mainboard program is not matching the head board logic. 13047_SOLUTION=Take note of the error code and contact your service representative. 13048_MODULE=Error 13048_TYPE=Software 13048_RESUME=System issue. (Altimeter detection issue.) 13048_REASON=Option 1: Altimeter detection issue.###Option 2: The firmware configuration is incorrect or corrupted. 13048_SOLUTION=Take note of the error code and contact your service representative. 13049_MODULE=Error 13049_TYPE=Software 13049_RESUME=Timeout when waiting for the motor to stop. 13049_REASON=Option 1: The parameter time for the firmware configuration is too short. 13049_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13050_MODULE=Error 13050_TYPE=Software 13050_RESUME=Carriage scale exit when the jitter is exceeding 1 second. 13050_REASON=Option 1: Motor or driver issue. 13050_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13051_MODULE=Error 13051_TYPE=Software 13051_RESUME=Failed to print. (Failed to read the PRN file data.) 13051_REASON=Option 1: The PRN file is used by another application and failed to open.###Option 2: The PRN file format is incorrect.###Option 3: The RIP software version is incorrect or has an issue.### 13051_SOLUTION=1. Check whether the PRN file is used by another application.###2. Establish whether the RIP software version is correct.###3. Try to restart the RIP and re-print..###4. Restart the UV Flatbed Controller and make a test print.###5. Restart the UV Flatbed Controller and the RIP.###If the error keeps reoccurring, take note of the error code and contact your service representative. 13052_MODULE=Error 13052_TYPE=Software 13052_RESUME=Failed to print. (Data processing error.) 13052_REASON=Option 1: The PRN file is used by another application and failed to open.###Option 2: The PRN file format is incorrect.###Option 3: The RIP software version is incorrect or has an issue.### 13052_SOLUTION=1. Check whether the PRN file is used by another application.###2. Establish whether the RIP software version is correct.###3. Try to restart the RIP and re-print..###4. Restart the UV Flatbed Controller and make a test print.###5. Restart the UV Flatbed Controller and the RIP.###If the error keeps reoccurring, take note of the error code and contact your service representative. 13053_MODULE=Error 13053_TYPE=Software 13053_RESUME=Failed to print. (Data processing error.) 13053_REASON=Option 1: The PRN file is used by another application and failed to open.###Option 2: The PRN file format is incorrect.###Option 3: The RIP software version is incorrect or has an issue.### 13053_SOLUTION=1. Check whether the PRN file is used by another application.###2. Establish whether the RIP software version is correct.###3. Try to restart the RIP and re-print..###4. Restart the UV Flatbed Controller and make a test print.###5. Restart the UV Flatbed Controller and the RIP.###If the error keeps reoccurring, take note of the error code and contact your service representative. 13054_MODULE=Error 13054_TYPE=Software 13054_RESUME=Failed to print. (Cut ink function data processing error.) 13054_REASON=Option 1: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 2: The firmware configuration and firmware parameters do not match. 13054_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13055_MODULE=Error 13055_TYPE=Software 13055_RESUME=Failed to print. (Pass mode not supported.) 13055_REASON=Option 1: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 2: The firmware configuration and firmware parameters do not match. 13055_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13056_MODULE=Error 13056_TYPE=Software 13056_RESUME=Failed to print. (PRN channels out of range.) 13056_REASON=Option 1: The PRN file format is incorrect###Option 2: The RIP software version is incorrect or has an issue. 13056_SOLUTION=1. Check whether the PRN file is used by another application.###2. Establish whether the RIP software version is correct.###3. Try to restart the RIP and re-print..###4. Restart the UV Flatbed Controller and make a test print.###5. Restart the UV Flatbed Controller and the RIP.###If the error keeps reoccurring, take note of the error code and contact your service representative. 13057_MODULE=Error 13057_TYPE=Software 13057_RESUME=Failed to print. (Data processing error.) 13057_REASON=Option 1: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 2: The firmware configuration and firmware parameters do not match.###Option 3: The software and the firmware configuration or firmware parameters do not match. 13057_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13058_MODULE=Error 13058_TYPE=Software 13058_RESUME=The software does not support the printer. 13058_REASON=Option 1: The software open method or the installation of the software is bad.###Option 2: The mainboard initialization parameters are incorrect or corrupted.### 13058_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13059_MODULE=Error 13059_TYPE=Software 13059_RESUME=Failed to print. (Print task issue.) 13059_REASON=Option 1: Print status issue. 13059_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13060_MODULE=Error 13060_TYPE=Software 13060_RESUME=Failed to print. (Print status issue.) 13060_REASON=Option 1: Print status issue. 13060_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13061_MODULE=Error 13061_TYPE=Software 13061_RESUME=Failed to print. (Print task issue.) 13061_REASON=Option 1: Print status issue. 13061_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13062_MODULE=Error 13062_TYPE=Software 13062_RESUME=Failed to print. (Print task is unavailable.) 13062_REASON=Option 1: Task file deleted. 13062_SOLUTION=If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13063_MODULE=Error 13063_TYPE=Software 13063_RESUME=Failed to print. 13063_REASON=Option 1: Failed to print, system issue.###Option 2: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameters.###Option 4: The UV Flatbed Controller version is not matching with the mainboard program version. 13063_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13064_MODULE=Error 13064_TYPE=Software 13064_RESUME=A print control thread error caused a print error and exit. 13064_REASON=Option 1: The mainboard version incorrect.###Option 2: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameters.###Option 4: The UV Flatbed Controller version is not matching with the mainboard program version. 13064_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13065_MODULE=Error 13065_TYPE=Software 13065_RESUME=Maine board or head board initialization issue. 13065_REASON=Option 1: The mainboard print initialization failed.###Option 2: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameters.###Option 4: The UV Flatbed Controller version is not matching with the mainboard program version. 13065_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13066_MODULE=Error 13066_TYPE=Software 13066_RESUME=Print control thread error. 13066_REASON=Option 1: The mainboard version is incorrect.###Option 2: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameters.###Option 4: The UV Flatbed Controller version is not matching with the mainboard program version. 13066_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13067_MODULE=Error 13067_TYPE=Software 13067_RESUME=Failed to print. (Print initialization error.) 13067_REASON=Option 1: The mainboard version is incorrect.###Option 2: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameters.###Option 4: The UV Flatbed Controller version is not matching with the mainboard program version. 13067_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13068_MODULE=Error 13068_TYPE=Software 13068_RESUME=Failed to print. (Waiting for a control thread when printing.) 13068_REASON=Option 1: The mainboard version is incorrect.###Option 2: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameters.###Option 4: The UV Flatbed Controller version is not matching with the mainboard program version. 13068_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13069_MODULE=Error 13069_TYPE=Software 13069_RESUME=Failed to print. (Printer idle.) 13069_REASON=Option 1: The mainboard print initialization failed.###Option 2: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameters.###Option 4: The UV Flatbed Controller version is not matching with the mainboard program version. 13069_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13070_MODULE=Error 13070_TYPE=Software 13070_RESUME=Failed to print. (Print initialization error.) 13070_REASON=Option 1: The mainboard print initialization failed.###Option 2: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameters.###Option 4: The UV Flatbed Controller version is not matching with the mainboard program version. 13070_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13071_MODULE=Error 13071_TYPE=Software 13071_RESUME=Failed to print. (Unknown print status.) 13071_REASON=Option 1: The mainboard print initialization failed.###Option 2: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameters.###Option 4: The UV Flatbed Controller version is not matching with the mainboard program version. 13071_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13072_MODULE=Error 13072_TYPE=Software 13072_RESUME=Failed to print. (Error sent.) 13072_REASON=Option 1: The mainboard print initialization failed.###Option 2: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameters.###Option 4: The UV Flatbed Controller version is not matching with the mainboard program version. 13072_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13073_MODULE=Error 13073_TYPE=Software 13073_RESUME=Print result error status. 13073_REASON=Option 1: The mainboard print initialization failed.###Option 2: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameters.###Option 4: The UV Flatbed Controller version is not matching with the mainboard program version. 13073_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13074_MODULE=Error 13074_TYPE=Software 13074_RESUME=The configuration of the vertical head spacing is not correct for this print mode. 13074_REASON=Option 1: The configuration of the vertical head spacing is incorrect for this print mode.###Option 2: The firmware configuration or the firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameters. 13074_SOLUTION=1. Check the software version information and confirm the first four digits are the same as the mainboard program version.###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 13075_MODULE=Error 13075_TYPE=Software 13075_RESUME=Printing is not possible in this system status. 13075_REASON=Option 1: The system is under the wetting mode, debug mode or reset mode so it cannot print. 13075_SOLUTION=Take note of the error code and contact your service representative. 13076_MODULE=Error 13076_TYPE=Software 13076_RESUME=The mainboard is not initialized. 13076_REASON=Option 1: The mainboard is not initialized.###Option 2: Mainboard parameter issue. 13076_SOLUTION=Take note of the error code and contact your service representative. 13077_MODULE=Error 13077_TYPE=Software 13077_RESUME=A reception error occurred when printing while using the RIP so the print was canceled automatically. 13077_REASON=Option 1: RIP software issue.###Option 2: Receiving abnormal module when printing with a RIP. 13077_SOLUTION=1. Check whether the PRN file is used by another application.###2. Establish whether the RIP software version is correct.###3. Try to restart the RIP and re-print..###4. Restart the UV Flatbed Controller and make a test print.###5. Restart the UV Flatbed Controller and the RIP.###If the error keeps reoccurring, take note of the error code and contact your service representative. 13078_MODULE=Error 13078_TYPE=Software 13078_RESUME=The mainboard upgrade failed. 13078_REASON=Option 1: The upgrade file is incorrect or corrupted.###Option 2: The UV Flatbed Controller version is not matching with mainboard program version. 13078_SOLUTION=Take note of the error code and contact your service representative. 03000_MODULE=Warning 03000_TYPE=Warning 03000_RESUME=Printing paused automatically. 03000_REASON=Option 1: The UV Flatbed Controller and the mainboard communication is unstable.###Option 2: The UV Flatbed Controller data transfer speed is insufficient. 03000_SOLUTION=1. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 03001_MODULE=Warning 03001_TYPE=Warning 03001_RESUME=Do not shutdown when upgrading the program. 03001_REASON= 03001_SOLUTION=Please wait until the current operation is finished. 03002_MODULE=Warning 03002_TYPE=Warning 03002_RESUME=The current operation execution failed. 03002_REASON=Option 1: The system is busy executing another action.###Option 2: This action cannot be executed in the current system status. 03002_SOLUTION=Please wait until the current operation is finished. 03003_MODULE=Warning 03003_TYPE=Warning 03003_RESUME=The configuration directory is unavailable.! 03003_REASON=Option 1: Mismatch between the UV Flatbed Controller and the firmware configuration version.###Option 2: The firmware configuration or firmware parameters is incorrect or corrupted.###Option 3: The installation of the UV Flatbed Controller is incorrect or there is a file directory missing. 03003_SOLUTION=Take note of the error code and contact your service representative. 03004_MODULE=Warning 03004_TYPE=Warning 03004_RESUME=The printer and the computer are disconnected. 03004_REASON=Option 1: The printer power is off.###Option 2: The printer and the software are disconnected.###Option 3: PC USB2.0 or 3.0 driver issue (USB communication). 03004_SOLUTION=1. Confirm the printer and the PC are connected. (Icon on the lower left corner of the software window.)###2. If the error keeps reoccurring after restarting the printer and the UV Flatbed Controller software, take note of the error code and contact your service representative. 03005_MODULE=Warning 03005_TYPE=Warning 03005_RESUME=The mainboard is not initialized. 03005_REASON=Option 1: Mainboard not initialized ###Option 2: Mainboard parameter error 03005_SOLUTION=Take note of the error code and contact your service representative. 03006_MODULE=Warning 03006_TYPE=Warning 03006_RESUME=System initialization action unfinished. 03006_REASON=Option 1: System initialization operation incomplete.###Option 2: The mainboard does not run normally.###Option 3: Firmware configuration and firmware parameter incorrect or corrupted. 03006_SOLUTION=Take note of the error code and contact your service representative. 03007_MODULE=Warning 03007_TYPE=Warning 03007_RESUME=Failed to restore the factory settings as the factory settings parameters are blanks. 03007_REASON=Option 1: The factory settings are not initialized and prevented a factory settings restoration. 03007_SOLUTION=Take note of the error code and contact your service representative. 03008_MODULE=Warning 03008_TYPE=Warning 03008_RESUME=Failed to restore the factory settings as the factory settings parameters are incorrect. 03008_REASON=Option 1: The factory settings parameters are incorrect or corrupted and it caused the failure of the factory settings restoration. 03008_SOLUTION=Take note of the error code and contact your service representative. 03009_MODULE=Warning 03009_TYPE=Warning 03009_RESUME=Failed to analyze the waveform data. 03009_REASON=Option 1: The connection between the mainboard and the head board is abnormal.###Option 2: The firmware configuration or firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching the head board logic.###Option 4: Waveform file issue or corruption. 03009_SOLUTION=Take note of the error code and contact your service representative. 03010_MODULE=Warning 03010_TYPE=Warning 03010_RESUME=Valid waveform type not created. 03010_REASON=Option 1: The system parameter waveform data is lost or corrupted. 03010_SOLUTION=Take note of the error code and contact your service representative. 03011_MODULE=Warning 03011_TYPE=Warning 03011_RESUME=Valid waveform data. 03011_REASON=Option 1: The system parameter waveform data is lost or corrupted. 03011_SOLUTION=Take note of the error code and contact your service representative. 03012_MODULE=Warning 03012_TYPE=Warning 03012_RESUME=Failed the waveform data analysis. 03012_REASON=Option 1: The system parameter waveform data is lost or corrupted.###Option 2: The system waveform data is not matching with the head board. 03012_SOLUTION=Take note of the error code and contact your service representative. 03013_MODULE=Warning 03013_TYPE=Warning 03013_RESUME=The waveform dot mode exceeds the maximum range. 03013_REASON=Option 1: The waveform data is incorrect or corrupted.###Option 2: The firmware parameter data is incorrect or corrupted.###Option 3: The system waveform data is not matching with the head board. 03013_SOLUTION=Take note of the error code and contact your service representative. 03014_MODULE=Warning 03014_TYPE=Warning 03014_RESUME=The carriage movement distance exceeded the X white margin position before executing the print task. 03014_REASON=Option 1: The carriage position is inconsistent with the X white margin position before executing the print task. 03014_SOLUTION=Please allow enough carriage acceleration distance when setting the white margin position. 03015_MODULE=Warning 03015_TYPE=Warning 03015_RESUME=The carriage movement distance exceeded the Y white margin position before executing the print task. 03015_REASON=Option 1: The carriage position is inconsistent with the Y white margin position before executing the print task. 03015_SOLUTION=Please allow enough carriage acceleration distance when setting the white margin position. 03016_MODULE=Warning 03016_TYPE=Warning 03016_RESUME=Parameter issue. (The X gear ratio is below zero.) 03016_REASON=Option 1: Parameter issue: the X gear ratio is below 0. 03016_SOLUTION=Take note of the error code and contact your service representative. 03017_MODULE=Warning 03017_TYPE=Warning 03017_RESUME=Flush trench setting parameter error. 03017_REASON=Option 1: The flush trench width setting is incorrect.###Option 2: The flush trench distance setting is incorrect. 03017_SOLUTION=Take note of the error code and contact your service representative. 03018_MODULE=Warning 03018_TYPE=Warning 03018_RESUME=Color bar parameter error. 03018_REASON=Option 1: A color bar parameter is incorrect.###Option 2: The firmware configuration or firmware parameters are incorrect or corrupted.###Option 3: The firmware configuration is not matching with the firmware parameter. 03018_SOLUTION=Take note of the error code and contact your service representative. 03019_MODULE=Warning 03019_TYPE=Warning 03019_RESUME=Failed to print. (The format exceeds the maximum motion distance.) 03019_REASON=Option 1: The print format exceeds the maximum motion distance.###Option 2: Carriage scale issue. 03019_SOLUTION=1. Check whether the white margin or print format exceeds the maximum motion distance of the printer.###2. Take note of the error code and contact your service representative. 03020_MODULE=Warning 03020_TYPE=Warning 03020_RESUME=Failed to print. (The image exceeds the media zone.) 03020_REASON=Option 1: X white margin parameter setting too large.###Option 2: The image width exceeds the media width. 03020_SOLUTION=1. Check whether the white margin or print format exceeds the maximum motion distance of the printer.###2. Take note of the error code and contact your service representative. 03021_MODULE=Warning 03021_TYPE=Warning 03021_RESUME=Failed to print. (The print width exceeds the maximum motion distance.) 03021_REASON=Option 1: X white margin parameter setting too large.###Option 2: The image width exceeds the media width.###Option 3: The firmware configuration or firmware parameters are incorrect or corrupted. 03021_SOLUTION=1. Check whether the white margin or print format exceeds the maximum motion distance of the printer.###2. Take note of the error code and contact your service representative. 03022_MODULE=Warning 03022_TYPE=Warning 03022_RESUME=Failed to print. (The print height exceeds the maximum motion distance.) 03022_REASON=Option 1: X white margin parameter setting too large.###Option 2: The image width exceeds the media width.###Option 3: The firmware configuration or firmware parameters are incorrect or corrupted. 03022_SOLUTION=1. Check whether the white margin or print format exceeds the maximum motion distance of the printer.###2. Take note of the error code and contact your service representative. 03023_MODULE=Warning 03023_TYPE=Warning 03023_RESUME=Waiting for RIP data. 03023_REASON=Option 1: Restart the RIP software. 03023_SOLUTION=1. Check whether the PRN file is used by another application.###2. Establish whether the RIP software version is correct.###3. Try to restart the RIP and re-print..###4. Restart the UV Flatbed Controller and make a test print.###5. Restart the UV Flatbed Controller and the RIP.###If the error keeps reoccurring, take note of the error code and contact your service representative. 03502_MODULE=Warning 03502_TYPE=Warning 03502_RESUME=Micro switch trigger 03502_REASON=Option1: X axis limit switch triggered.###Option2: Y axis limit switch triggered. 03502_SOLUTION=1. Move the carriage manually to the center of the print table and re-start the printer.###2. If the error reoccurs, write down the error code and contact your service representative. 03503_MODULE=Warning 03503_TYPE=Warning 03503_RESUME=The initialization failed. 03503_REASON=Option 1: Communication issue on the mainboard, head boards or optical fibers.###Option 2: Broken optical fiber or optical fiber link. 03503_SOLUTION=Take note of the error code and contact your service representative. 03504_MODULE=Warning 03504_TYPE=Warning 03504_RESUME=Z axis position initialization failed. 03504_REASON=Option 1: Issue with the Z axis motor. ###Option 2: Motor driver error. ###Option 3: abnormal lower limit of the carriage. 03504_SOLUTION=Take note of the error code and contact your service representative. 03505_MODULE=Warning 03505_TYPE=Warning 03505_RESUME=X or Y axis reverse motion initialization failed. 03505_REASON=Option 1: X axis reverse movement issue.###Option 2: Y axis reverse movement issue. 03505_SOLUTION=1. Check whether the servo working state is normal. If it is abnormal, please restart the device. ###2. Take note of the error code and contact your service representative. 03506_MODULE=Warning 03506_TYPE=Warning 03506_RESUME=X or Y axis slow motion initialization failed. 03506_REASON=Option 1: X axis slow motion issue.###Option 2: Y axis slow motion issue. 03506_SOLUTION=1.Please move the carriage on the table and please restart the device.###2. Check whether the servo working state is normal. If it is abnormal, please restart the device. ###3. Take note of the error code and contact your service representative. 03507_MODULE=Warning 03507_TYPE=Warning 03507_RESUME=X or Y axis origin position motion initialization failed. 03507_REASON=Option 1: X axis origin position initialization issue.###Option 2: Y axis origin position initialization issue. 03507_SOLUTION=1. Check whether the servo working state is normal. If it is abnormal, please restart the device. ###2. Take note of the error code and contact your service representative. 03508_MODULE=Warning 03508_TYPE=Warning 03508_RESUME=Z axis down initialization failed. 03508_REASON=Option 1: Z axis motor issue.###Option 2: Z axis motor drive issue.###Option 3: Abnormal upper limit of the carriage. 03508_SOLUTION=Take note of the error code and contact your service representative. 03509_MODULE=Warning 03509_TYPE=Warning 03509_RESUME=Abnormal print head board link lamp. 03509_REASON=Option 1: Abnormal head board connection. 03509_SOLUTION=Take note of the error code and contact your service representative. 01004_MODULE=Information 01004_TYPE=Status 01004_RESUME=System Information-Mainboard Initialization Successfully 01004_REASON= 01004_SOLUTION= 01005_MODULE=Information 01005_TYPE=Status 01005_RESUME=System Information - Factory Initialization Successful 01005_REASON= 01005_SOLUTION= 01006_MODULE=Information 01006_TYPE=Status 01006_RESUME=System Information-Device Connection 01006_REASON= 01006_SOLUTION= 01007_MODULE=Information 01007_TYPE=Status 01007_RESUME=System Information-The spray plate fiber connection is successful and the spray plate is successfully initialized. 01007_REASON= 01007_SOLUTION= 01008_MODULE=Information 01008_TYPE=Status 01008_RESUME=System Information-The lower computer is initialized and the parameters are automatically loaded... 01008_REASON= 01008_SOLUTION= 01009_MODULE=Information 01009_TYPE=Status 01009_RESUME=System Information-Wait for the fiber optic connection signal of the spray plate... 01009_REASON= 01009_SOLUTION= 01010_MODULE=Information 01010_TYPE=Status 01010_RESUME=System Information-Device Connection, Autoload Parameters... 01010_REASON= 01010_SOLUTION= 01011_MODULE=Information 01011_TYPE=Status 01011_RESUME=System Information-Load Parameters... 01011_REASON= 01011_SOLUTION= 01012_MODULE=Information 01012_TYPE=Status 01012_RESUME=System Information-Enter Reset Mode 01012_REASON=Option 1. DIP switch is ON-ON 01012_SOLUTION=1. Restore the DIP switch to 1-2 01013_MODULE=Information 01013_TYPE=Status 01013_RESUME=System Information-Entering the Mode 01013_REASON=Option 1, the DIP switch is ON-2 or 1-ON 01013_SOLUTION=1. Restore the DIP switch to 1-2 01014_MODULE=Information 01014_TYPE=Status 01014_RESUME=Write Flash successfully 01014_REASON= 01014_SOLUTION= 01015_MODULE=Information 01015_TYPE=Status 01015_RESUME=System Information-Reading Flash Successfully 01015_REASON= 01015_SOLUTION= 01016_MODULE=Information 01016_TYPE=Status 01016_RESUME=System Information-Execute Initialization Action... 01016_REASON= 01016_SOLUTION= 01017_MODULE=Information 01017_TYPE=Status 01017_RESUME=System Information-Performed Initialization Action Successful 01017_REASON= 01017_SOLUTION= 01018_MODULE=Information 01018_TYPE=Status 01018_RESUME=System Information-Keyboard modification parameters, automatic loading parameters... 01018_REASON= 01018_SOLUTION= 01019_MODULE=Information 01019_TYPE=Status 01019_RESUME=System initialization action is prohibited 01019_REASON= 01019_SOLUTION= 01020_MODULE=Information 01020_TYPE=Status 01020_RESUME=System Information - System Initialization Completed 01020_REASON= 01020_SOLUTION= 02000_MODULE=Information 02000_TYPE=Execution 02000_RESUME=The motherboard and the expansion board communicate abnormally. 02000_REASON= 02000_SOLUTION= 02001_MODULE=Information 02001_TYPE=Execution 02001_RESUME=System Information-System Initialization... 02001_REASON= 02001_SOLUTION= 02002_MODULE=Information 02002_TYPE=Execution 02002_RESUME=System Information - Printing is cancelled 02002_REASON= 02002_SOLUTION= 02003_MODULE=Information 02003_TYPE=Execution 02003_RESUME=Write Flash... 02003_REASON= 02003_SOLUTION= 02004_MODULE=Information 02004_TYPE=Execution 02004_RESUME=System Information - User cancels printing 02004_REASON= 02004_SOLUTION= 12013_MODULE=Error 12013_TYPE=Hardware 12013_RESUME=Safety cover exception 12013_REASON=Option 1.Detect that the safety cover is opened. 12013_SOLUTION= 12900_MODULE=Error 12900_TYPE=Hardware 12900_RESUME=Abnormal power supply (undervoltage, overvoltage, etc.) 12900_REASON=Possible 1. Undervoltage, overvoltage and overcurrent of the spray plate or driving plate power supply 12900_SOLUTION=Please check whether the power supply of spray plate and drive plate is under voltage, over voltage or over current 12901_MODULE=Error 12901_TYPE=Hardware 12901_RESUME=Insufficient printed data 12901_REASON=Possible 1. Parameter Settings are incorrect###2.The optical fiber is in poor contact¡£###3.Excessive waveform frequency 12901_SOLUTION=Please check whether the parameter Settings are incorrect###2.Check whether the optical fiber interfaces are improperly connected during the printing process¡£###3.During the printing process, check whether the optical fiber port is properly connected 12902_MODULE=Error 12902_TYPE=Hardware 12902_RESUME=Print overclocking 12902_REASON=Possible 1. Spray plate parameter setting is wrong. ###2. Waveform overfrequency. 12902_SOLUTION=Please check whether the spray plate parameter setting is wrong and whether the waveform is overclocked 12903_MODULE=Error 12903_TYPE=Hardware 12903_RESUME=Grating polarity anomaly 12903_REASON=Possible 1. The grating polarity does not match the print direction 12903_SOLUTION=Check that the grating polarity matches the print direction 12904_MODULE=Error 12904_TYPE=Hardware 12904_RESUME=Instant power failure 12904_REASON=Possible 1. The switching power supply is faulty 12904_SOLUTION=Check whether the switching power supply is faulty 12905_MODULE=Error 12905_TYPE=Hardware 12905_RESUME=Insufficient printing travel 12905_REASON=Possible 1. Raster decoder is abnormal.###2.Limit contact is poor¡£###3.Motor motion anomaly 12905_SOLUTION=Please check whether the grating decoder is abnormal and calibrate the gear ratio###2.Please check whether the motor limit is triggered###3.Please check whether the motor is in poor contact 12906_MODULE=Error 12906_TYPE=Hardware 12906_RESUME=The communication of the expansion board is abnormal 12906_REASON=Possible 1. The data cable between the mainboard and expansion board is damaged. ###2. Poor contact of data cable interface. 12906_SOLUTION=Check whether the data cable between the mainboard and the expansion board is intact and whether the interface of the data cable is in poor contact 12907_MODULE=Error 12907_TYPE=Hardware 12907_RESUME=Jet plate grating count is abnormal 12907_REASON=Possible 1. Raster decoder is abnormal. 12907_SOLUTION=Please check whether the raster decoder is abnormal 12908_MODULE=Error 12908_TYPE=Hardware 12908_RESUME=Communication link down 12908_REASON=Possible 1. The cable connection between the main board and the spray plate is loose, and the contact is poor###2.The expansion board's cable is loose, and the contact is poor 12908_SOLUTION=Please check whether the cables of the main board and spray plate, expansion board are loose or in bad contact 12909_MODULE=Error 12909_TYPE=Hardware 12909_RESUME=The packet reversion is abnormal 12909_REASON=Possible 1. The communication cable is aged, and the cable port is faulty 12909_SOLUTION=Check the quality of the communication cable, whether it is aged, and whether the cable interface is faulty 12910_MODULE=Error 12910_TYPE=Hardware 12910_RESUME=The packet error statistics are abnormal 12910_REASON=Possible 1. The communication cable is aged, and the cable port is faulty 12910_SOLUTION=Check the quality of the communication cable, whether it is aged, and whether the cable interface is faulty ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////// 12920_MODULE=Error 12920_TYPE=Hardware 12920_RESUME=Nozzle Power Supply Error (VDD) 12920_REASON=Possible 1.Nozzle Power Supply Error (VDD) 12920_SOLUTION=Check whether the power supply of the sprinkler is normal 12921_MODULE=Error 12921_TYPE=Hardware 12921_RESUME=Nozzle Power Supply Error(VH) 12921_REASON=Possible 1.Nozzle Power Supply Error(VH) 12921_SOLUTION=Check whether the power supply of the sprinkler is normal 12922_MODULE=Error 12922_TYPE=Hardware 12922_RESUME=Nozzle Power Supply Error(JCOM) 12922_REASON=Possible 1.Nozzle Power Supply Error(JCOM) 12922_SOLUTION=Check whether the power supply of the sprinkler is normal 12923_MODULE=Error 12923_TYPE=Hardware 12923_RESUME=Spray board power supply error(overvoltage) 12923_REASON=Possible 1.Spray board power supply error(overvoltage) 12923_SOLUTION=Please check whether the spray board power supply is normal 12924_MODULE=Error 12924_TYPE=Hardware 12924_RESUME=Spray board power supply error(undervoltage) 12924_REASON=Possible 1.Spray board power supply error(undervoltage) 12924_SOLUTION=Please check whether the spray board power supply is normal 12925_MODULE=Error 12925_TYPE=Hardware 12925_RESUME=Spray board power supply error(overcurrent) 12925_REASON=Possible 1.Spray board power supply error(overcurrent) 12925_SOLUTION=Please check whether the spray board power supply is normal 12926_MODULE=Error 12926_TYPE=Hardware 12926_RESUME=The nozzle row is inserted incorrectly 12926_REASON=Possible 1.The nozzle row is inserted incorrectly 12926_SOLUTION=Check whether the nozzle cable is connected properly 12927_MODULE=Error 12927_TYPE=Hardware 12927_RESUME=The grating count of the spray plate is abnormal 12927_REASON=Possible 1.The grating interface of the spray plate is loose###2.Twisted pair cables are not used 12927_SOLUTION=Please check whether the grating interface of the spray plate is normal and whether the twisted pair is used 12928_MODULE=Error 12928_TYPE=Hardware 12928_RESUME=X motor limit trigger causes motor stop 12928_REASON=Possible 1.X limit error trigger possible###2.Raster decoder exception¡£ 12928_SOLUTION=Please check that the raster decoder is abnormal and that the X motor limit is triggered 12929_MODULE= Error 12929_TYPE= Hardware class 12929_RESUME= The sprinkler type is inconsistent 12929_REASON= Possible 1. Whether the driver nozzle is correct ### Possible 2. Firmware spray car configuration error ### May 3. Not the manufacturer waveform 12929_SOLUTION=1. Re-import the correct firmware configuration file and firmware parameter file ###2. Re-import or apply the manufacturer's waveform file 04000_MODULE=Error 04000_TYPE=Hardware 04000_RESUME=Cap Sensor Loss 04000_REASON=Possible 1. Limit not connected or damaged ### Possible 2. Ink stack motor not connected or damaged 04000_SOLUTION=Please check the limit sensor and motor for problems 04001_MODULE=Error 04001_TYPE=Hardware 04001_RESUME=Y_O Sensor Loss 04001_REASON=Possible 1. The limit is not connected or damaged 04001_SOLUTION=Please check the limit sensor 04002_MODULE=Error 04002_TYPE=Hardware 04002_RESUME=Y_F Sensor Loss 04002_REASON=Possible 1. The limit is not connected or damaged 04002_SOLUTION=Please check the limit sensor 04003_MODULE=Error 04003_TYPE=Hardware 04003_RESUME=Grating Loss 04003_REASON=Possible 1. The motor is not connected ### Possible 2. The grating polarity is reversed 04003_SOLUTION=Please check the motor connection or select the correct grating polarity 04004_MODULE=Error 04004_TYPE=Hardware 04004_RESUME=X Sensor Loss 04004_REASON=Possible 1. The limit is not connected or damaged 04004_SOLUTION=Please check the limit sensor 13080_MODULE= Error 13080_TYPE= Hardware 13080_RESUME= Abnormal paper 13080_REASON= Possible 1. The paper bulge may be offset. 13080_SOLUTION=1. Check whether the paper is placed correctly 12002_MODULE=Error 12002_TYPE=Hardware 12002_RESUME=Print failed, paper shortage detected 12002_REASON=Possible 1. There is no paper 12002_SOLUTION=1. Please supplement the materials. ###2. Please check whether the missing paper sensor is normal. ###3. Please check whether the wiring of the sensor is correct. 12625_MODULE = Error 12625_TYPE = Hardware 12625_RESUME = Abnormal communication with the expansion board 12625_REASON = Possible cause 1: Abnormal connection between the expansion board and the main board 12625_SOLUTION = 1. Check the connection between the expansion board and the main board