Page 31 of 66

dislocation.
Pulse direction(dir): adjust the direction of axis.
Key direction(dir): change the direction of the keys. If it is
found that the up and down or so key direction inside out, and
back to zero normal word, change the parameters, is normal.
Initial speed: set the initial speed of the shaft began, usually
set 10 mm/s. General scope for the 5 mm/s to 30 mm/s.
Acceleration(acc): the acceleration of the shaft running. General
step motor with 500 mm/s2 to 2000 mm/s2. Typical values for 1500
mm/s2. Servo motor using a wide range, in the 500 mm/s2 to 5000
mm/s2. Typical values for 2000 mm/s2.
Maximum speed: set the speed of the shaft's largest can run.
Maximum acceleration: the shaft maximum acceleration can run.
Depending on the motor ability of the equipment. This parameter
is used to specify the scope of the maximum speed of the shaft.
Debugging good generally do not need to change.
Max jerk: can set the shaft's largest run and acceleration.
Depending on the motor ability of the equipment. This parameter
is used to specify the scope of the maximum speed of the shaft.
Debugging good generally do not need to change.
Home when : : allows boot back to zero. No: boot back to zero.
Home enabled: : then the axis allowed back to zero. No: the shaft
back to zero.
Home speed: back to zero.
Home return distance: the X axis is set the distance between the
origin and back to zero position.
The laser parameters:
The laser mode: which related to the laser power supply interface
connection. If the connection is simulated, the simulation, if the