Page 30 of 70

Shenzhen Zhiyuan CNC Co., Ltd
ZY72B8G System Manual
correct pulse equivalent.
Fallback Dis
mm
The distance from the origin switch
after returning to zero is usually set
appropriately. Usually set at around
5mm.。
Home speed
mm/s
Set the speed when returning to zero.
The speed cannot be set too high,
usually 30mm/s to 50mm/s.
Zero return
yes/no
Yes: then the axis is allowed to return
enable
to zero. No: Cancel the zero return of
the axis.
Gap
mm
The user compensates for the reverse
compensation
clearance of the device.
initial speed
mm/s
Set the initial speed for starting the
axis, usually set at 10mm/s. The
general range is between 5mm/s and
30mm/s.
Acc
mm/s²
The acceleration of single axis
movement. Generally, stepper
motors use 500mm/s ² To
2000mm/s ² That's it. Typical value is
1500mm/s ²。 The servo motor has a
Shenzhen Zhiyuan CNC Co., Ltd
25