Appendix 3 Interpretation of Wiring Connection between F2000 Series and Common THC
A3.4 Connection with ONTIME THC
F2000 output ports
Plasma arc starting 16
Lock THC
18
Torch up
02
Torch down 15
24VG
13
F2000 input ports
Arcing feedback
04
24VG
13
ONTIME AVC103(CON1)
4
START ARC
1
AUTO
2
UP
3
DOWN
6
COM
5
MOTION
Plasma parameter
Delay Before Arc
Pierce time
Range of value
0
0
Recommended value
0
0
Torch up time
0-3
3
Arcing Check Time:
5-30
30
Position check Time:
0
0
Speed to lock THC
90-100
95
Distance to lock THC
0-15
10
Lose arc delay
0-1
0.5
Watch arc enable
Yes
Yes
The method of setting parameter:
F2100T, F2200T, F2300 T (A/B), F2500 T (A/B), F2600T:
F4 (Setups), F3 (Plasma).
Input definition
Port
Position detect
05
Output definition
Port
Lock THC
18
Type
Type
The method of definition:
129
    "