15
Cutting torch is 1High sensitiveness of high adjusting machineregulate
unsteadily
in RP501
automation
2damage of high adjusting machine
16
High
adjusting 1High sensitiveness of high adjusting machineregulate
machine is too slow to RP501
follow in automation
17
No arc during the causecan not stop immediately since the high adjusting
incision, the are machine is are voltage signal.
voltage is continued to resolutionadopt the arc feedback signal of Plasma itself
produce and the
machine is still work
9.2、Cancel Extinguished Arc and Improve Function
If the ascending function of cutting torch has not been installed properly
the down-up is easy to block by boot-strap, you can cancel the function in the
main control board.
There are two ways to cancel the function:
1、Cancel the R234 in the main board
2、Cancel the C218 in the main board
9.3、Several Proposal
1、When we use the IHS of Torch Retaining Cap, install the anti-bump clamp
and connect to protect the Torch Retaining Cap, in this way it is more useful
to safeguard the cutting torch.
2、When we use the Proximity switch, we suggest to use the PNP model. The
ways as below shows:
23
    "