15
Cutting torch is 1、High sensitiveness of high adjusting machine,regulate
unsteadily
in RP501
automation
2、damage of high adjusting machine
16
High
adjusting 1、High sensitiveness of high adjusting machine,regulate
machine is too slow to RP501
follow in automation
17
No arc during the cause:can not stop immediately since the high adjusting
incision, the are machine is are voltage signal.
voltage is continued to resolution:adopt the arc feedback signal of Plasma itself
produce and the
machine is still work
9.2、Cancel Extinguished Arc and Improve Function:
If the ascending function of cutting torch has not been installed properly
the down-up is easy to block by boot-strap, you can cancel the function in the
main control board.
There are two ways to cancel the function:
1、Cancel the R234 in the main board
2、Cancel the C218 in the main board
9.3、Several Proposal
1、When we use the IHS of Torch Retaining Cap, install the anti-bump clamp
and connect to protect the Torch Retaining Cap, in this way it is more useful
to safeguard the cutting torch.
2、When we use the Proximity switch, we suggest to use the PNP model. The
ways as below shows:
23