9、Fault Maintenance
9.1、Frequent Fault Examination
Serial
Malfunction
Cause
Resolution
Number
1
No display, black No +5V voltage on the Check +5V voltage VCC3
screen
voltage meter
2
No revolution of 1、 damage of drive 1、replace IR2110
generator or only
IR2110
one
direction 2、 drive voltage +15V, Check drive voltage VCC4
rotates.
failure
3、 protection
of D606 ∽ D609 ( IRF640 ) is
over-current
damaged or mechanical
blocked
3
Once open the 1.Proximity switch is Install the Proximity
power, the incision not installed well in switch perfectly
part continue to the
open-circuit
move up 。(NPN) condition
2、damage of Proximity Replace Proximity switch
switch
(signal:2mm,NPN)
4
Can not produce arc 1、damage of Proximity Replace Proximity switch
automatically
switch, no return
after the IHS
signal
2 、 IHS time is too Prolong the IHS switch
short, no return signal
5
Instability
of 1、check the connection with earth
controlling voltage 2、check the air-proof
3、over-sensitiveness
21