P12 0 或 1 1 P13 0 或 1 1 P14 150 1 50 P15 1100 1 100 (Page 22 / 46) Portable Plasma Torch Height Controller Manual F1620

Portable Plasma Torch Height Controller Manual (F1620)
P12 0 或 1
1
P13 0 或 1
1
P14 1-50 1 50
P15 1-100 1 100
P16 0.1-2 0.01 0.2
P17 0-10 0.1 1
P18 0.1-1 0.1 2
0
P19 0-9.9 0.01 0
9
P20 0-20 0.1 6
collision halt signal to CNC during
torch work.
P12 1 Switching motor contrary or positive
direction of rotating. Instead of
changing wiring, changing this
parameter can change the motor
direction of rotating.
P13 1 Enable the proximity switch collision
check. When user set it as 1, the
proximity switch collision check is
allowed.
P14 50 Brake speed adjust step and length.
When set it as 50, brake speed is
fastest.
P15 100 Speed adjust step and length when
motor turn contrary. The bigger value
can make reversal transition speed
become more and more smaller.
P16 0.2 Unit:Second(S). Arc voltage delay
time of setting.
P17 1.0 Unit:Second(S). The lifting time of
starting up.
P18 2.0 Unit : Second(S).The time of
promoting the spear after torch have
P19 0
accomplished
Unit : Second(S).Torch lifting time
when arc start start to work.
P20 6.0 Unit : Second(S). The time of
descending rapidly during the dual
speed IHS.
Parameter explain particularly:
1. P00:Recovering factory parameter. P00 can display 1. If user set it as 0 and
save this parameter, all kinds of parameter in our equipment will recover factory
parameter. After user exit the submenu, they can find that P00 display 1.
2. P01,P02,P03,P04:Setting manul lifting and auto lifting speed of torch. The
minimum speed is 0, the maximum speed is 50.
3. P05: The value of promoting arc voltage. During torch is cutting, if gun of
13
    "