The user needs to set parameters before using. Click [System
Parameters] to set.
Double click light extraction enabling: The enabling is opened,
double click the button for twice to extract light, close the enabling
button, click once to extract light.
Scale factor: X system parameter is changed to 680;
Y system parameter is changed to 750.
Parameter No.
scan type
Scanning speed
Laser power
Laser frequency
Duty ratio
Second length:
scan width:
Safety lock
Flow alarm
Temperature
XXX℃
Underpressu
Lraesearlaarlmarm
Galvanometer
alarm
System settings
Red light | on
Stop cleaning
Double click light
extraction enabling
Time for enabling
gas in advance (ms)
Time for delay in
disenabling gas (ms)
X-axis scaling factor
Y-axis scaling factor
Enabling the
safety lock
Language
Disable
Simplified
Chinese
Phase Increment
Fill spacing
Corner delay
Equipment parameter
Authorization
Back
Chapter IX Monitoring and Protection
Device
9.1 Temperature parameter setting of protective glass
[Home
Page]→[System
Parameter]→[Equipment
Parameter]→[Input Password: 666888] →next page→ lens
temperature alarm limit value.
It is suggested to set the set value of lens temperature to 50. After the
lens temperature exceeds the set value, the alarm caution will arise on the
home page and the display light on the side of the handheld plumb joint
42