Page 37 of 45
![](RustOff%2C%20FWH20-DC30A%20Intelligent%20Double%20Pendulum%20Handheld%20Cleaning%20Head.pdf-37.html%20-%20foldersweb.png)
Shenzhen RelFar Intelligent Technology Co., Ltd.
length allowed by the equipment
Laser rated power: It is used for setting the rated power of the laser.
Maximum laser frequency: It is used to set the maximum laser
frequency
Minimum laser frequency: It is used to set the minimum laser frequency
Laser alarm enabling: It is used to set whether to enable laser alarm. If
this parameter is enabled, a laser alarm will be generated when the laser
alarm input triggers the alarm.
Laser alarm level: It is used to set the laser alarm that triggers the
electrical level logic.
Water-cooling machine alarm enabling: It is used to set whether to
enable water-cooling machine. If this parameter is enabled, a water-
cooling machine will be generated when the water-cooling machine input
triggers the alarm.
Water-cooling machine alarm level: It is used to set the water-cooling
machine that triggers the electrical level logic.
Underpressure alarm enabling: It is used to set whether to enable
underpressure alarm. If this parameter is enabled, an underpressure alarm
will be generated when the underpressure alarm input triggers the alarm.
Underpressure alarm level: It is used to set the underpressure alarm that
triggers the electrical level logic.
Temperature alarm enabling: It enables the lens temperature alarm.
37