PWM frequency set by welding parameter exceeds the maximum frequency, the
frequency will be limited to the maximum value.
Maximum swing length: set the maximum length during swing. When the length
set by welding parameter exceeds the maximum length, the length will be limited to
the maximum length.
Wire feeding step: used to set the step during motor wire feeding.
Direction of motor wire feeding: used to set the direction polarity of motor wire
feeding.
Galvanometer correction coefficient: when there is a nuance in the set length and
the actual length, it can be modified by this parameter. When there is no need for
correction, it is usually set as 1.
Lens temperature alarm enable: enable lens temperature alarm. When the
temperature exceeds the limited value, the alarm signal will be generated.
Lens temperature alarm limited value: the limited value of lens temperature
Laser alarm enable: used to enable laser alarm. When laser generates alarm, the
alarm signal will be generated.
Laser alarm level: used to set laser alarm to trigger the level logic.
Water-cooling machine alarm enable: used to enable water cooling machine alarm.
When the water cooling machine generates alarm, the alarm signal will be generated.
Water-cooling machine alarm level: used to set water-cooling machine alarm to
trigger the level logic.
Low pressure alarm enable: used to enable gas alarm. When gas low pressure
generates alarm, the alarm signal will be generated.
Low pressure level: used to set low pressure alarm to trigger the level logic.