深圳市睿法智能科技有限公司
Swing length: used to set motor swing length
Wire feeding parameter: used to set system parameter, including wire feeding,
slow rise and fall parameters
Light emission time: the time that processing lasts when single point welding
mode is set.
7.2.2Point welding mode: click to enter the single point light emission mode
System parameter: used to set the basic parameters of device. Generally, the
setting is performed by manufacturers. Before entering the page, users need to enter
password.
System password: 666888
Pulse on time: the time to start light emission in pulse mode
Pulse off time: the time to stop light emission in pulse mode
Slow rise time: used to set the time that the laser analog voltage rises from initial
power to the maximum power when it is enabled.
Slow fall time: used to set the time that laser analog voltage falls from the
maximum power to initial power when it is stopped.
Light on power: used to set the initial power of laser, the percentage of welding
power
Light on asymptotic time: the time to control the light on power of laser to rise
slowly to the set power
Light off power: used to set the light off power of laser, the percentage of welding
power
Light off asymptotic time: the time to control the light off power to fall slowly
Language: to switch language
Advance gas on delay: when starting processing, users can set gas activation
delay. When the external start button is pressed, after blowing delay for some time,
the laser can emit light.
Gas off delay: when stopping processing, users can set gas closure delay. When
processing is stopped, stop the laser first. After delay for some time, stop gas blowing.
26
    "