深圳市睿法智能科技有限公司
water flow alarm, laser alarm and temperature alarm status will be displayed in real
time. When the safety lock is started, its status will be displayed in real time. When
the alarm signal is not triggered, the alarm icon is blue; when it is triggered, the alarm
icon is blue and red alternately.
Homepage/ Wire feeding parameter/ Diagnosis/ System parameter: to display the
type of parameter on the current page. Click an icon to enter the switch of the
corresponding parameter page. For instance, if the icon on the homepage turns on, the
parameter in the current display area is the parameter of the homepage. When it needs
to switch to wire feeding parameter, just click the position of wire feeding, and the
icon of this parameter will turn on.
Blowing manually/ Wire feeder: for manual blowing test and the wire feeding and
wire withdrawing tests of wire feeder. For example, long press manual blowing key,
and it will blow all the time; loosen this key, and it ill stop blowing. For manual wire
feeding and wire withdrawing, long press the corresponding small triangle area.
7.2HMI operation introduction
7.2.1Parameter setting:
Parameter setting includes: Home page, System parameter, Wire feeding
parameter and Diagnosis page
Home page: used to set parameters related to laser, swing and process library
when welding.
Process library: click the white box area in process library. The set process library
parameter can be selected.
Welding model: to set welding mode, continuous and pulse modes.
Power: to set the peak power of laser when welding
PWM frequency: used to set the frequency of laser PWM modulating signal
Duty cycle: used to set duty cycle of PWM signal with the range from 1% to
100%
Swing frequency: used to set motor swing frequency
25
    "