Page 28 of 37
![](FWH30-D20C%20%E7%9D%BF%E6%B3%95%E5%8F%8C%E6%91%86%E6%89%8B%E6%8C%81%E7%84%8A%E6%8E%A5%E5%A4%B4%E8%8B%B1%E6%96%87%E8%AF%B4%E6%98%8E%E4%B9%A6%EF%BC%88%E5%8F%8C%E9%80%81%E4%B8%9D%E5%9B%9B%E5%90%88%E4%B8%80%EF%BC%89A%E7%89%88%E6%9C%AC%202024-02-24.pdf-28.html%20-%20foldersweb.png)
Language: Used for language switch.
Delay when the gas is enabled in advance: Delay in enabling gas can be set when
processing is enabled. The emission of laser will start after blowing is delayed for a period of time
by pressing the external start button.
Delay when the gas disabling is delayed: Delay in disenabling gas can be set when
processing is disenabled. Stop blowing after stopping laser emission, and then delaying for a
period of time when processing is stopped.
Automatic swing: Used for automatic swing when the galvanometer is set; Enable the
automatic swing. When the breakover of the safety lock arises, the automatic swing of the
galvanometer will happen. In case of no breakover of the safety lock, the galvanometer motor
won't swing automatically after delay for a period of time.
Equipment parameters: Used to switch to equipment parameter page, with password input.
Authorized by: Used for mainboard authorization management.
Device number: Used to set the Bluetooth number of control system. When the user has
several pieces of equipment, the number can be freely defined for management.
Center bias: Used to set the red light center bias.
7.2.3 [Wire feeding parameter]: Used to set the wire feed parameters,
such as wire supplement parameter and wire withdrawal parameter.
Wire withdrawing speed: Motor wire withdrawal speed after the starting switch is loosened.
Time of wire withdrawal: Time of motor wire withdrawal.
Wire supplement speed: Speed of motor wire supplement.
Time of wire supplement: Time of motor wire supplement.
Wire feed delay time: Wire feed after delay for a period of time after laser emission which is
generally 0.
Continuous wire feed: Used for wire change of wire feeder. Continuous wire feed will arise
by clicking once, and continuous wire feed will stop by clicking anew.
Continuous wire withdrawal: Used for wire change of wire feeder. Continuous wire
withdrawal will arise by clicking once, and continuous wire feed will stop by clicking anew.
[Diagnosis]: Used to monitor the current system IO state.
28