7.2.4 [Equipment parameter]: Used to set relevant parameters of the
equipment.
Rated power of laser: Used for setting the rated power of the laser.
Maximum deflection of the galvanometer: Used for setting the maximum deflection scope
of the galvanometer.
Maximum laser frequency: Set the maximum frequency of laser PWM signal. When the set
PWM frequency of welding parameter exceeds the maximum frequency, the PWM frequency will
be restricted to the maximum frequency.
Maximum swing length: Set the maximum length at the moment of swinging. When the set
length of welding parameter exceeds the maximum length, the length will be restricted to the
maximum length.
Wire feed step: Step at the time of motor wire feed.
Wire feed motor direction: Setting the direction polarity of the motor wire feed.
Galvanometer compensation coefficient X: If the length set by X axis is inconsistent with
actual length, with a small difference, the correction can be performed by the parameter.
Galvanometer compensation coefficient Y: If the length set by Y axis is inconsistent with
actual length, with a small difference, the correction can be performed by the parameter.
Lens temperature alarm enabling: It enables the lens temperature alarm. When the
temperature exceeds the limit value, an alarm signal will be generated.
Lens temperature alarm limit: Lens temperature limit value.
Laser alarm enabling: Enable the laser alarm. When the laser gives an alarm, an alarm
signal will be produced.
Laser alarm level: Laser alarm logic level.
Cooling-water machine alarm enabling: Enable the cooling-water machine alarm. When
the cooling-water machine gives an alarm, an cooling-water machine signal will be produced.
Cooling-water machine alarm level: Cooling-water machine alarm logic level.
Underpressure alarm enabling: Enable the gas alarm. When an alarm is given due to the
gas underpressure, an alarm signal will arise.
Underpressure alarm level: Under pressure alarm logic level.