Welding mode: Setting the welding mode: Continuous, pulse mode.
Laser power: Set the peak power of the laser at the moment of welding.
Laser frequency: Set the laser PWM modulating signal frequency.
Duty ratio: Set the duty ratio of PWM modulating signal, with setting range:
1%~100%.
Swinging frequency: It is to set the swing frequency of motor.
Swing length: It is to set the swing width of motor.
Wire feeding speed: Set the wire feed speed at the time of welding.
Time of laser emission: Time of laser emission under the mode of spot welding.
Spot welding mode: Enter the spot welding laser emission mode.
Swing type: Set the motor swing graphics. Support ‘—’‘○’‘ ’‘∞’、,
’.
7.2.2 [System parameter]: Used to set the basic parameters of the equipment,
configured by the manufacturer generally. The passport needs to be input before entering the page.
System entry password: 666888 (six-digit figures).
Pulse enabling time: Time of laser emission under the pulse mode.
Pulse disenabling time: Pulse disabling time under the pulse mode.
Slow rise time: Used to set the time of slow increase from the initial power to the maximum
power when the laser analog voltage is enabled.
Slow descent time: Used to set the time of slow decrease from the maximum power to the
initial power when the laser analog voltage is disenabled.
Laser enabling power: Used to set the initial power of laser, it is the percentage of the
welding power.
Time of advancing gradually when laser enabling: Control the time taken for the laser
emission of the laser to slowly rise to the set power.
laser disenabling power: Used to set the laser disenabling power, it is the percentage of the
welding power.
Time of advancing gradually when laser disenabling: Control the time taken by the laser
disabling power of laser to slowly lower.
27
    "