Shenzhen RelFar Intelligent Technology Co., Ltd.
Automatic screen lock: When the automatic screen lock is enabled, the
system automatically switches to the screen lock page when no operations
are performed on the touchscreen after a period of time.
[Authorization]: Perform authorization code reading and decryption
operations, and display the information about the panel and mainboard
version numbers.
7.3 Equipment parameters
[Equipment parameters]: It is used to limits the maximum and
minimum parameters. This parameter limits the laser parameters, only by
entering the password to enable it. After the parameter is changed, it must
be saved to take effect.
Maximum scanning speed: It is used to set the maximum oscillating
speed of the galvanometer
Minimum scanning speed: It is used to set the minimum oscillating
speed of the galvanometer
Maximum scanning length: It is used to set the maximum scanning
length allowed by the equipment
Minimum scanning speed: It is used to set the minimum scanning
length allowed by the equipment
Laser rated power: It is used for setting the rated power of the laser.
Maximum laser frequency: It is used to set the maximum laser
frequency
Minimum laser frequency: It is used to set the minimum laser frequency
Laser alarm enabling: It is used to set whether to enable laser alarm. If
this parameter is enabled, a laser alarm will be generated when the laser
alarm input triggers the alarm.
Laser alarm level: It is used to set the laser alarm that triggers the
electrical level logic.
Water-cooling machine alarm enabling: It is used to set whether to
enable water-cooling machine. If this parameter is enabled, a
water-cooling machine will be generated when the water-cooling machine
input triggers the alarm.
Water-cooling machine alarm level: It is used to set the water-cooling
machine that triggers the electrical level logic.
Underpressure alarm enabling: It is used to set whether to enable
underpressure alarm. If this parameter is enabled, an underpressure alarm
will be generated when the underpressure alarm input triggers the alarm.
Underpressure alarm level: It is used to set the underpressure alarm that
29
    "